Specifications 

(Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

High-speed function 

(high speed recording)

Time axis

100μs to 100ms/div, 10 range, resolution: 100 points/div

Sampling period

1/100 of time axis ranges

 

(minimum sampling period 1 μs, all channels simultaneously)

Recording length

5 to 10000 divisions fixed 

(5division steps)

Automatic save func-

tion

Binary data, text data, calculation results, calculation results, 

text + calculation results, or NONE

Other save functions

Save and delete function: ON/OFF

Screen settings

Split screen 

(1, 2, or 4 segments)

, X-Y waveform compositing 

(1 screen)

Pre-trigger

Can record data from before the trigger point, 0 to 100 % of 

recording length; 13 settings, or user-configured

Waveform scrolling

Backwards scrolling through past waveform data both during and 

after measurement

Calculation functions

Up to four arithmetic operations simultaneously

Average value, effective (RMS) value, peak to peak value, 

maximum value, time to maximum value, minimum value, time to 

minimum value, period, and frequency, area, X-Y area.

Real-time function 

(actual time recording)

Recording interval

100μs to 500μs, 1ms to 500ms, 1s to 1min, 19 settings

Display time axis: 10ms to 1day/div, 22 ranges

Real-time printing 

(with optional MR9000)

ON/OFF

*Simultaneous printing: Supported when using a time axis slower than 1 s/div.

Recording Time

Continuous save to CF card or USB memory can be set ON/OFF

Envelope mode

ON/OFF

Waveform recording

The last 1 Mwords 

(before measurement was stopped)

 are saved in 

the instrument’s internal memory 

(when envelope mode is on, 500 

kwords).

Real-time save func-

tion

Binary data, text data, calculation results, calculation 

results, text + calculation results, or NONE

Other save functions

Split save: ON/OFF/fixed time

Save and delete: ON/OFF

Eject media: Media can be ejected while saving data in real time.

Event marks

1) Event marks can be input during measurement (up to 100 marks).

2) Can move to waveform before or after an event mark based on 

specified event number input.

Trigger function

Repeat recording 

Single/Repeat

Trigger timing

High-speed function: Start

Real-time function: Start, Stop, Start & Stop

Trigger conditions

AND/OR supported for all trigger sources

Trigger source

Trigger sources can be selected for each channel. Instrument enters 

free-run mode when all trigger sources are off. 

1) Analog input CH1 - CH4

2) Logic input LA1 - LA4, LB1 - LB4 (4ch × 2 probes)

3) External trigger

4) Interval trigger: Fixed-time recording for specified measurement 

interval (month/day/hours/minutes/seconds)

Trigger types

1) Level

2) In

3) Out

4) Voltage drop 

(High-speed function) : For AC 50/60 Hz power lines

5) Waveform judgment 

(High-speed function): For AC 50/60 Hz power lines

6) Logic

7) External: Rising edge/falling edge

Level setting resolution

0.1 % f.s. 

(f.s.=10 div)

Trigger filter

High-speed function: 7 settings from 10 to 1000 samples or OFF

Real-time function: ON/OFF

Trigger output

Open collector (5 V output, active Low)

Analog input

(Accuracy defined at 23° ±5°C, 80% rh or less, for measurements taken following 

zero adjustment 30 minutes  after instrument is turned on)

Measurement 

functions

4-channel voltage measurement; switchable between instantaneous 

value (waveform) and RMS value

Input connectors

Isolated BNC connector 

(input impedance 1 MΩ, input capacitance 7 pF)

Max. rated voltage to 

earth

600 V  AC, DC  CAT III  / 300 V  AC, DC  CAT IV 

(with input isolated from the unit, the maximum voltage that can be applied between 

input channel and chassis and between input channels without damage)

Measurement range

10 mV to 100 V/div, 13 ranges, full scale: 10 div, AC voltage that can 

be measured and displayed using high-speed function: 600 Vrms

Low-pass filter: 5 Hz/50 Hz/500 Hz/5 kHz/50 kHz

Measurement resolu-

tion

1/640 of measurement range 

(using 14-bit A/D conversion, at × 1)

Highest sampling rate

1 MS/s 

(simultaneous sampling in 4 channels)

Instantaneous value 

measurement accuracy

±0.5% f.s. (after zero-adjust)

RMS measurement

RMS accuracy: ±1.5% f.s. 

(30Hz to 1kHz)

 ±3% f.s. (

1kHz to 10kHz)

Response time: 300ms 

(rising edge 0 to 90% of full scale with filter off)

Crest factor: 2

Frequency charac-

teristics

DC to 100 kHz ±3dB

Input coupling

DC/GND

Max. rated voltage 

between terminals

600 V AC, DC  

(maximum voltage which when applied to between input 

terminals does not damage them)

Basic specifications

Measurement func-

tions

High-speed function (high speed recording)

Real-time function (actual time recording)

Number of channels

4  8 logic

Isolated analog channels, isolated input and outputs, logic has common GND.

Maximum sampling rate

1Msamples/s (1 μs cycle, all channels simultaneously)

Memory capacity

14bit × 1 M words/ch (1 word = 2 bytes, not expandible)

External memory

CF card slot × 1 (Up to 2 GB, supports FAT16 and FAT32 formats)

USB memory × 1 (USB 2.0 -A receptacle)

Time accuracy 

(at 23°C)

Sampling time accuracy: ±0.0005 %, Clock precision: ±3s/day

Backup function

(reference value at 

23°C)

Clock and settings: 10 years or more (at 25°C / 77°F)

Waveform backup function: Approx.  40 minutes

• 

When instrument is powered off at least 3 minutes after being turned on

External control

External trigger input, Trigger output, external start input, external 

stop input, status output, ground pin

Interface

USB: 1 port USB 2.0 High Speed mini-B receptacle

Functions: Configure settings/perform measurement using communications 

commands: transfer file stored in CF/USB memory to computer (USB drive 

mode)

Environmental condi-

tions for use

(no condensation)

Temperature range: -10°C (14°F) to 50°C (122°F)

Humidity range: -10°C (14°F) to 40°C (104°F), 80% rh or less

                             40°C (104°F) to 45°C (113°F), 60% rh or less 

                             45°C (113°F) to 50°C (122°F), 50% rh or less

When powered by BATTERY PACK Z1000: 

                               0°C (32°F) to 40°C (104°F), 80% rh or less

When recharging the Z1000: 10°C (50°F) to 40°C (104°F), 80% rh or less

Environmental condi-

tions for storage

(no condensation)

Temperature range: -20°C (-4°F) to 60°C (140°F)

Humidity range: 80% rh or less (-20°C (-4°F) to 40°C (104°F)), 60% rh 

or less 

(40°C (104°F) to 45°C (113°F)), 50% rh or less (45°C (113°F)  to 60°C 

(140°F))

BATTERY PACK Z1000: -20°C (-4°F) to 40°C (104°F) , 80% rh or less

Compliance

standard

Safety: EN61010    EMC: EN61326, EN61000-3-2, EN61000-3-3

Vibration resistance: JIS D 1601, Type 1: passenger vehicle, 

Conditions: equivalent to Type A

Power requirements

Note: LR6/AA alkaline batteries 

are not sufficient to power the 

unit when it is connected with 

the Printer Unit MR9000.  Use of 

other power supplies is required.

(Continuous operating time is 

given as a reference value at 23°C.)

1) 

AC ADAPTER Z1002

: 100 to 240V AC (50/60 Hz)

2) 

BATTERY PACK Z1000

: 7.2V DC  

  Continuous operating time: Approx. 3 hours with backlight on, approx. 

3.5 hours with backlight off 

(AC adapter has priority when both are used)

3) LR6 (AA)×8 

 Approx. 40 minutes with backlight on. Approx. 50minutes with  back-

light off. 

(when used with AC adapter, AC adapter takes precedence)

4) 10 to 28V DC (using special order cable)

Charging functions

(reference value at 23°C)

Charging time is about 3 hours

(can be charged by connecting the AC adapter while the Z1000 battery 

pack is attached)

Max. rated power

1) When instrument is powered with the Z1002 AC adapter or an  

    external DC power supply: 11 VA*

1

, 10 VA*

2

, 40 VA*

3

2) When instrument is powered with the Z1000 battery pack; 

     9 VA*

1

, 8 VA*

2

, 22 VA*

3

 

  *

Real-time data storage, backlight on

  *

Real-time data storage, backlight off

  *

Real-time data storage, backlight on, with printer used

Dimensions, mass

(including battery pack)

205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 1.66 kg 

(58.6 oz) (printer detached)

303 mm (11.93 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D,2.16 kg 

(76.2 oz) (printer attached)

Accessories

Instruction manual ×1, AC adapter Z1002 ×1, Alkaline battery box 

×1, Strap ×1, USB cable ×1, Application disk (Wave viewer Wv, 

Communication commands table) ×1

Function

Presets

Select from basic measurement guide, example measurement guide, 

and commands for loading internally stored settings.

Scaling function

Select decimal or scientific notation for each channel.

1) Scaling ratio: Select scaling ratio, offset value, and units.

2) Two-point configuration: Set input values, post-scaling values, 

and units.

3) HIOKI sensor: Set HIOKI clamp-on probe and range value.

4) Output rate setting: Select scaled value per 1 V from a list. 

Data protection

Open files are closed before the instrument turns itself off when a 

power outage occurs while saving data to recording media. When 

powering the instrument with a battery, open files are closed and access 

to the media is stopped when remaining battery power falls below a 

certain level. 

*Valid when at least 3 minutes has elapsed since the instrument was turned on.

 

Reservation function

Up to 10 measurement start and measurement stop conditions can be set.

Other

Settings can be automatically loaded from internal memory or 

media when the instrument is turned on. Up to 10 settings can be 

saved in the instrument’s internal memory.

Printer  

(Printer Unit MR9000 docks onto the main device)

Features

Printer paper one-touch loading, high-speed thermal printing

Printer paper

112 mm (4.4 in) × 18 m (59.06 ft), thermal paper roll (using 9234)

Recording width: 100 mm, 10 div f.s., 1 div=10 mm (80 dot/div)

Recording speed

Max. 10 mm/s (0.39 inch/s) 

(Printing is not supported when using alkaline batteries.)

Summary of Contents for MR8880

Page 1: ...te settings The re corder can be easily configured to measure voltage drops and power outages Maximum 600V AC DC input no need for a differential probe 4 completely isolated channels let you simultane...

Page 2: ...22 F Even when operating on battery power the MR8880 can take measurements from 0 C 32 F to 40 C 104 F n Rugged damage resistant design features standard side protectors that guard the instrument s ca...

Page 3: ...the channel you wish to use Select the power line voltage Select the frequency Select the threshold Select the high speed or real time function The auto range settings can be enabled when using the hi...

Page 4: ...S s 500 s 8m 20 s 100ms DIV 1 kS s 1 ms 16m 40 s The maximum recording length is fixed regardless of the number of channels in use Measure RMS value fluctuations for a power line over an extended peri...

Page 5: ...aking measurements in an outdoor setting The dis play is even engineered for easy viewing in the presence of reflections a What if there s no power available in the vehicle being tested A high capacit...

Page 6: ...annels isolated input and outputs logic has common GND Maximum sampling rate 1Msamples s 1 s cycle all channels simultaneously Memory capacity 14bit 1 M words ch 1 word 2 bytes not expandible External...

Page 7: ...en and 8 k or lower short Response speed 500ns or lower Max allowable input 0 to 50V DC the maximum voltage that can be applied across input pins without damage LOGIC PROBE MR9321 01 Function Detectio...

Page 8: ...0 02 Select between WAVE RMS mode For the Memory HiCorder series input up to 1kV AC DC AC ADAPTER Z1008 100 to 240 V AC Voltage to ground is within this product s specifications Separate power source...

Reviews: