Hioki MEMORY HiCORDER MR8880 Quick Start Manual Download Page 8

St

or

ag

e m

edi

a

Use only CF Cards or USB drive sold by HIOKI. Compatibility and 

performance are not guaranteed for CF cards/USB memory stick 

made by other manufacturers. You may be unable to read from or 

save data to such cards.

PC CARD 2G 9830

  2 GB capacity

PC CARD 1G 9729

  1 GB capacity

PC CARD 512M 9728

  512 MB capacity

USB DRIVE Z4006

  16 GB, Long-life, High-reliability 

SLC Flash Memory

Includes a PC card adapter with the 9728/9729, and  the 9830

Leak Current 

*For commercial power lines, 50/60 Hz

CLAMP ON LEAK HiTESTER  3283

  10 mA range/10 μA resolution to 200 A range, 

with monitor/analog output 1 V f.s.

OUTPUT CORD  L9095

  Connect to BNC terminal, 1.5 m (4.92 ft) length

AC ADAPTER  9445-02

  100 to 240 V AC

AC ADAPTER  9445-03

  For EU 100 to 240 V AC

Non

-co

nta

ct V

olta

ge m

eas

urin

g

NON-CONTACT AC VOLTAGE 

PROBE SP3000-01

 5 Vrms rated, 10 Hz to 100 kHz 

band width

NON-CONTACT 

AC VOLTAGE 

PROBE SP3000

 Sold individually

AC VOLTAGE 

PROBE 

SP9001

 Sold individually

The CM7290 (available separately) is required in order to use these current sensors.

500 A to 5000 A 

*For commercial power lines, 50/60 Hz

CLAMP ON PROBE  9018-50

  Good phase characteristics, Frequency 

characteristics: 40 Hz to 3 kHz, 10 to 500 A 

AC range, output 0.2 V AC f.s.

CLAMP ON PROBE  9132-50

  Frequency characteristics: 40 Hz to 1 kHz, 

20 to 1000 A AC range, output 0.2 V AC f.s.

AC FLEXIBLE CURRENT SENSOR  

CT9667-01/-02/-03

  10 Hz to 20 kHz, 5000 A/ 500 A AC, 500 

mV/f.s. output, φ 100 to 254 mm (3.94 to 

10.00 in), 3 loop diameters

100 A to 2000 A (Medium speed)

AC/DC CURRENT SENSOR CT7631, 

(Auto zero  CT7731)

 DC, 1 Hz to 10 kHz (-3dB), 100 A, 1 mV/A output

AC/DC CURRENT SENSOR CT7636, 

(Auto zero  CT7736)

 DC, 1 Hz to 10 kHz (-3dB), 600 A, 1 mV/A output

AC/DC CURRENT SENSOR CT7642, 

(Auto zero  CT7742)

 DC, 1 Hz to 10 kHz (5 kHz), 2000 A, 1 mV/A output

DISPLAY UNIT CM7290

 Provides measurement, display, and output 

functionality when used with the CT7000s.

DISPLAY UNIT CM7291

 with built-in Bluetooth® wireless technology

OUTPUT CORD  L9095

  Connect to BNC terminal, 1.5 m (4.92 ft) length

Precautions when connecting a high-precision current sensor to a Memory HiCorder

Connecting to the MR8880/MR8875/MR8870

• High-precision current sensor (ME15W) + BNC cable 

 MR8880

• High-precision current sensor (PL23) + BNC cable 

 MR8880

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.

*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x.

*The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.

POWER SUPPLY for Current Sensors

SENSOR UNIT CT9555

 1ch, with Waveform output

CONNECTION CORD L9217

 

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

PL23 (10-pin) - ME15W (12-pin) conversion

CONVERSION CABLE CT9900

  Convert  PL23 (10-pin) terminal to ME15W (12-pin) terminal

Up to 1000 A (High precision) 

*ME15W (12-pin) terminal type

High-precision pull-through type, monitor the waveforms of DC to distorted AC current

AC/DC CURRENT SENSOR  CT6875

, 2 MHz band width, 500A

Monitor the waveforms of DC to distorted AC current

AC/DC CURRENT PROBE  CT6844-05

, 200 kHz band width, 500A

AC/DC CURRENT PROBE  CT6845-05

, 100 kHz band width, 500A

AC/DC CURRENT PROBE  CT6846-05

, 20 kHz band width, 1000A

Other current sensor types

The MR8880 can be used with various types of current sensors and 

probes. For details, see product information on Hioki’s website.

Po

w

er

 s

uppl
y

AC ADAPTER Z1002

 

For main unit, 100 to 240 V 

AC

BATTERY PACK Z1000

  NiMH, Charges while 

installed in the main unit

*Z1002 is a bundled accessory

Pr

in

te

r op
tion
s

PRINTER UNIT MR9000

  Printing width 100 mm (3.94 in), 

used together with the MR8880-

20 main body, includes 1 roll of 

recording paper

RECORDING PAPER 9234

  112 mm (4.41 in) × 18 m (59.06 ft), 

roll type, 10 rolls/set

Ot

he

r op
tion

s

CARRYING CASE 

C1003

 Includes compartment for 

options, soft case type

CONNECTION CORD 

L9217

 Cord has insulated BNC 

connectors at both ends, for 

signal output, 1.6 m (5.25 ft) 

length

In

pu

t c

abl
e (

E)

 

DIFFERENTIAL PROBE 9322

  For up to 1kV AC or 2kV DC, 

frequency band width up to 10MHz

 

AC ADAPTER 9418-15

  100 to 240 V AC.

*Voltage to ground is within this product's specifications. 

Separate power source is also required.

Cus

tom

 cabl

e

*For P9000. Inquire with your Hioki distributor.

(1) 

Bus powered USB cable

(2) 

USB(A)- Micro B cable

(3) 

3-prong cable

In

pu

t c

abl
e (

D)

DIFFERENTIAL PROBE 

P9000-01

 

Waveform only, up to 1 kV AC/

DC, band width up to 100kHz

DIFFERENTIAL PROBE 

P9000-02

  Waveform/RMS value switch-

able, up to 1 kV AC/DC, band 

width up to 100kHz

AC ADAPTER 

Z1008

  100 to 240 V AC

*Voltage to ground is within this product's specifications. 

Separate power source is also required.

In

pu

t c

abl
e (

B)

*Voltage is limited to the specifications of the input section

CONNECTION CORD  L9198

  φ 5.0 mm (0.20 in) dia., cable allowing 

for up to 300 V input. 1.7 m (5.58 ft) 

length, small alligator clip

CONNECTION CORD  L9197

  φ 5.0 mm (0.20 in) dia., cable allowing 

for up to 600 V input. 1.8 m (5.91 ft) 

length, a detachable large alligator 

clips are bundled

GRABBER CLIP  9243

  Attaches to the tip of the banana 

plug cable, CAT III 1000 V, 196 

mm (7.72  in) length

CONNECTION CORD  L9790

  Flexible φ 4.1 mm (0.16 in) thin 

dia., cable allowing for up to 600 

V input. 1.8 m (5.91 ft) length

* The end clip is sold separately.

ALLIGATOR CLIP  L9790-01

  Red/black set attaches to the ends 

of the cables L9790

GRABBER CLIP  9790-02

 

Red/black set attaches to the ends 

of the cables L9790

* When this clip is attached to the end of the 

L9790, input is limited to CAT II 300 V. 

Red/black set.

CONTACT PIN  9790-03

 

Red/black set attaches to the ends 

of the cables L9790

L9790-01

9790-02

9790-03

L9790

In

pu

t c

abl
e (

A)

*Voltage is limited to the specifications of the input section

Recommended

MR9000

Model : MEMORY HiCORDER MR8880

Model No. (Order Code) (Note)

MR8880-20

(4ch, printer unit option)

*Test leads are not included. Purchase the leads appropriate for 

your application separately

MR8880  Options in Detail

Logic signal measurement

LOGIC PROBE  MR9321-01

  4 isolated channels, ON/OFF 

detection of AC/DC voltage 

(miniature terminal type)

LOGIC PROBE  9320-01

4-channel type, for voltage/contact signal 

ON/OFF detection (response pulse width 

500 ns or more, miniature terminal type)

* Only the small terminal types can be used.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for MEMORY HiCORDER MR8880

Page 1: ...ropriate settings The re corder can be easily configured to measure voltage drops and power outages Maximum 600V AC DC input no need for a differential probe 4 completely isolated channels let you sim...

Page 2: ...ng on battery power the MR8880 can take measurements from 0 C 32 F to 40 C 104 F n Rugged damage resistant design features standard side protectors that guard the instrument s case n 4 analog 8 logic...

Page 3: ...o use Select the power line voltage Select the frequency Select the threshold Select the high speed or real time function The auto range settings can be enabled when using the high speed function Make...

Page 4: ...ms DIV 1 kS s 1 ms 16m 40 s The maximum recording length is fixed regardless of the number of channels in use Measure RMS value fluctuations for a power line over an extended period of time Long term...

Page 5: ...an outdoor setting The dis play is even engineered for easy viewing in the presence of reflections a What if there s no power available in the vehicle being tested A high capacity battery is availabl...

Page 6: ...and outputs logic has common GND Maximum sampling rate 1Msamples s 1 s cycle all channels simultaneously Memory capacity 14bit 1 M words ch 1 word 2 bytes not expandible External memory CF card slot 1...

Page 7: ...etectable pulse width 500 ns or longer Max allowable input 0 to 50V DC the maximum voltage that can be applied across input pins without damage LOGIC PROBE MR9321 01 Function Detection of AC or DC rel...

Page 8: ...to distorted AC current AC DCCURRENTPROBE CT6844 05 200kHzbandwidth 500A AC DCCURRENTPROBE CT6845 05 100kHzbandwidth 500A AC DCCURRENTPROBE CT6846 05 20kHzbandwidth 1000A Other current sensor types Th...

Reviews: