Instruction Manual

IM9201

SMD TEST FIXTURE

July 2016  Edition 1
IM9201A961-00  16-07H

Summary of Contents for IM9201

Page 1: ...EN Instruction Manual IM9201 SMD TEST FIXTURE July 2016 Edition 1 IM9201A961 00 16 07H...

Page 2: ......

Page 3: ...impedance analyzer carefully Contents Verifying Package Contents p 2 Safety Information p 3 Operating Precautions p 4 Product Overview p 5 Names and Functions of Parts p 6 Measuring Method p 7 Measur...

Page 4: ...4 Knob for fixing tip pin 1 Tip pin 2 3 Brush for cleaning 1 4 Hex driver 1 5 Carrying case 1 6 Instruction Manual 1 GND plate and device guide for the sizes 1005 0402 1608 0603 2012 0805 3216 1206 32...

Page 5: ...WARNING Indicates a potentially hazardous situation that may result in death or serious injury to the operator CAUTION Indicates a potentially hazardous situation that may result in minor or moderate...

Page 6: ...not press the tip pin in the electrode when the DUT is not attached While pressing the tip pin into the DUT the DUT may pop out To avoid injuries lower the pusher slowly and press the tip pin into th...

Page 7: ...5 2 5 0 15 H 0 4 L W H Tip pins device guides and plates for each DUT size DUT size JIS EIA Accessories 0603 0201 1005 0402 1608 0603 2012 0805 3216 1206 3225 1210 Tip pin 3225 3216 1005 1608 2012 322...

Page 8: ...lacing the GND plate and DUT on top of the electrode 7 Model IM9906 Adapter 3 5 mm 7 mm The exclusive adapter for connecting the device to the test head of the impedance analyzer side 8 Test head The...

Page 9: ...er See the instruction manual of the impedance analyzer Test head 2 Attach the test head and adapter to the stand Attach the test head and model IM9906 Adapter to the model IM9200 Test Fixture Stand M...

Page 10: ...lution Is the short plate worn Compare the resistance value with the new or a non defective short plate Replace with new short plate if the resistance value is high Is the tip pin deformed If the tip...

Page 11: ...d Model IM9200 1 2 Metal fittings 1 Pull the metal fittings to the model IM9200 Test Fixture Stand side 2 Place the test head on the stand and tighten the knob Model IM9906 Notch Measuring terminal 3...

Page 12: ...ay cause damage to the electrode When the calibration cannot be executed Confirm that the calibration kit and model IM9906 Adapter are connected properly Check that the DC measurement limit value of t...

Page 13: ...ration by using the impedance analyzer 2 1 0 0 3 4 Nut 7 Short calibration kit 9 7 Remove the open calibration kit by turning the nut of the open calibration kit 8 Place the short calibration kit on t...

Page 14: ...only the nut of load calibration kit while pressing the top part of the load calibration kit If the top part of the load calibration kit is rotated the internal conductors of the calibration kit and a...

Page 15: ...ower the bolt thread by turning the nut of model IM9906 Adapter 3 2 2 2 Loosen the stand fixing knob 3 Place the device on the model IM9200 Test Fixture Stand As shown in figure slide the notch part 4...

Page 16: ...Correction The error caused by the phase shift occurring between the calibration reference surface and the measurement DUT s connection surface is compensated Set the electrical length correction to...

Page 17: ...ility You will need Hex driver 1 Tweezers 1 This is not provided with the device Tweezers which are thinner than the DUT size clean and not magnetized are recommended Device guide and short plate 1 ea...

Page 18: ...lts However measurement error may increase due to variability in the short plate s inductance 2 3 4 5 6 Short plate 2 Remove four bolts by using the hex driver 3 Remove the device guide and GND plate...

Page 19: ...tip pin is finalized fix it by turning the knob and lower the pusher 12 Execute short correction by using the impedance analyzer When the correction cannot be executed Confirm that the short calibrati...

Page 20: ...608 2012 0603 3225 3216 1005 1608 2012 GND plate At the time of open correction and measurement 0603 3225 3216 1005 1608 2012 0603 3225 3216 1005 1608 2012 0603 3225 3216 1005 1608 2012 0603 3225 3216...

Page 21: ...hod 7 Start the open correction in the impedance analyzer 1 2 3 4 5 6 When correction cannot be executed check that the DC measurement limit value of the impedance analyzer is appropriate 9 8 7 6 5 4...

Page 22: ...t location remove it 2 2 Pick up the DUT with tweezers and set it to the measurement location of device guide Keep the surface with electrode facing down Set the DUT perpendicular to the frame of the...

Page 23: ...mm 1608 0603 1 6 0 15 0 8 0 1 mm H 0 4 mm 2012 0805 2 0 0 15 1 25 0 15 mm H 0 4 mm 3216 1206 3 2 0 15 1 6 0 15 mm H 0 4 mm 3225 1210 3 2 0 15 2 5 0 15 mm H 0 4 mm The measurement unit of size 3225 121...

Page 24: ...parts used in the product may deteriorate with extended use To ensure the product can be used over the long term it is recommended to replace these parts on a periodic basis When replacing parts plea...

Page 25: ...16 01 EN...

Page 26: ......

Page 27: ......

Page 28: ......