36
7.2.2
OPERATIONS FROM GROUND CONTROL POSITION
EMERGENCY POTENTIAL SITUATIONS:
Operator illness
Remote control breakdown
CONDITIONS REQUIRED:
Engine and/or electric motor properly working
Electrical system properly functioning
Machine properly stabilized
The main purpose of using the ground control position is to rescue the operator
staying in the basket. To use the ground control position to move the aerial
part machine must be stabilized, in particular all the stability conditions must
be respected except for the remote control position.
To use
the ground control position it’s necessary to ignite engine or electric
motor and to keep turned rightward the control position selector while acting
on the aerial part valveblock levers.
NOTE: If the ground control box is closed, it must be opened with its key.
NOTE: Operating from the ground control box engine carter/lithium pack
contact prevention system is bypassed.
NOTE: On lithium machines, turning rightward the control position selector will
also make the electric motor run at minimum speed, if machine is stabilised.
CONTROL POSITION
SELECTOR SWITCH
AERIAL PART MOVEMENTS LEVERS
MOTORS INGNITION
BUTTONS
AERIAL PART MOVEMENTS INDICATIONS
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...