INTAKE (J05E)
9–35
REPLACEMENT
EN01F02114080402009003
REMOVING THE AIR FLOW SENSOR
1.
DISCONNECTING THE HARNESS
(1)
Disconnect the connector connected to the air flow sensor.
2.
Removing the air flow sensor
(1)
Unfasten the screws (2 pcs.) securing the air flow sensor, and
remove it.
MOUNTING THE AIR FLOW SENSOR
1.
MOUNTING THE AIR FLOW SENSOR
(1)
Make sure that the O-ring is attached to the air flow sensor, and
mount the air flow sensor with screws (2 pcs.).
Tightening Torque:
0.56-0.82 N·m {5.8-8.3 kgf·cm, 0.42-0.60 lbf·ft}
! CAUTION
Do not apply excessive torque to the air flow sensor mounting
screw (M 3.5) when tightening it.
2.
CONNECTING THE HARNESS
(1)
Connect the connector to the air flow sensor.
CONNECTOR
AIR FLOW
SENSOR
SHTS021270800051
CONNECTOR
AIR FLOW
SENSOR
SHTS021270800052