ii) Fit the bottom inlet ball valve in left 
or right side (depends upon the water 

connection line) & other side hole 
should be plugged with PVC plug.

iv) Fit the dual flush knob 

on lid & screw with the 

beta valve bracket for the 

fitment of lid on Cistern 

shell.

Make  the  outlet  line  of  EWC  and  

fixing  hole  postions  on  the  floor  

with  marker  pen  after  placement  of  

complete  set.

Remove  the  EWC  set  and  make  the  

hole  on  marked  postion  with  the  help  

of  5  mm  drill  bit  and  put  sleeves  into  

the  drilled  hole.

Again  place  the  EWC  set  on  

marked  position  and  fit  t he  screw  

in  the  hole  s o  that  it  can  be  

tightened  inside  the  sleeves .

FLOOR FIXING

1

2

3

CAUTION
Do not fill cement mortar inside the bottom of EWC otherwise due to  expansion of cement, crack may develop in the closet foot.

Rubber  gasket  should  be  used 

with  waste  outlet  Connect  the  water  

connection  with  the  flexible  

connecting  pipe.

STEPS FOR INSTALLING 'P' TRAP

STEPS FOR INSTALLING 'S' TRAP

Height of centre of outlet to floor to 

be made as mentioned in (A)

A

B

3

2

4

Distance between face of outlet pipe to 

wall as mentioned in (B) Accordingly 

outlet to be provided in the wall.

C

The outlet hole should be made on floor 

as mentioned in (C )

4

i) Fit the brass bolt in the 

holes of Cistern with washer 

& nut to couple the Cistern 

with EWC.

iii) Fit the beta valve in the 

central outlet hole & tight 

the checknut at the bottom 

of cistern.

v) Put both the buttons 

(6L/3L) inside the dual 

flush Knob.

All the fitting components should be fitted as mentioned below.

1

STEPS FOR INSTALLATION

RECOMMENDED STANDARD SPECIFICATION TABLE  FOR EWC P/S WITH CISTERN

D

(It is recommended to check with sanitaryware physically.)

It is suggested to  fit 

the seat cover 

before 

installation

S. No.

Cat. No.

Description 

 Centre of outlet

Dist. Between

For S-Trap 

For S-Trap

 to floor

 For P-Trap 

(A)

 face of outlet to

Dist  between

face of outlet to

finished wall (B)

centre of outlet

floor (D)

to wall (C)

1.

20041 & 21028

EWC STUDIO/ VISTA with Cistern 

190 mm ±5 mm

135 mm

110 mm ±10 mm

20 mm ±5 mm

2.

20049 & 21030

EWC MATRIX with Cistern 

180 mm ±5 mm

125 mm

110 mm ±10 mm

20 mm ±5 mm

3.

20050 & 21034/21033

EWC CLEO with Cistern 

Not Applicable

Not Applicable

220 mm ±10 mm

20 mm ±5 mm

4.

20065 & 21045

EWC PLUTO with Cistern 

Not Applicable

Not Applicable

110 mm ±10 mm

20 mm ±5 mm

5.

20066 & 21044

EWC VENUS with Cistern 

190 mm ±5 mm

125 mm

110 mm ±10 mm

20 mm ±5 mm

6.

92026 &92106

EWC CLIPPER with Cistern (S-200) 

Not Applicable

Not Applicable

220 mm ±10 mm

20 mm ±5 mm

7.

92058 & 92122 

EWC FLORENCE WITH CISTERN

Not Applicable

Not Applicable

220 mm ±10 mm

20 mm ±5 mm

8.

92077 & 92128

EWC GRACIA WITH CISTERN

Not Applicable

Not Applicable

110 mm ±10 mm

20 mm ±5 mm

9.

92073 & 92126

EWC CLIPPER WITH CISTERN (S-100)

Not Applicable

Not Applicable

100 mm ±10 mm

20 mm ±5 mm