Appendix A – Near Lightning Strike Test
This appendix describes the general procedure for evaluating the immunity to near lightning strikes (NLS) of
the HM130 VHF Radio.
The test simulates a slow, high-energy pulse produced by an NLS event.Relative external document as below
BS EN 61000-4-5 : 2006
EMC Directive 2004/108/EC
List of Abbreviations
AE
Auxiliary Equipment
CE
Conducted Emissions
EMC
Electromagnetic Compatibility
EN
European Norm
EUT
Equipment Under Test
FTB
Fast Transient Burst
MED
Marine Equipment Directive
QP
Quasi Peak
Safety
The high voltage interference pulse can contain a very large quantity of energy and every precaution shall be
taken to avoid contact with EUT during a test. It is highly recommended that at least one other person is
present (or very close by) during the test.
Test Configuration
EUT Setup
The EUT shall be setup in a typical system configuration on an isolated wooden bench with NO
GROUNDPLANE. The power to the EUT and auxiliary equipment shall be from 12V or 24V sealed lead-acid
batteries via a suitable fuse. The length of the EUT power cable shall be no more than 2m. Any screens within
the system shall be terminated at the battery –vet connection.