background image

1

CLT-50AT-RE

Power Controller
TLF series Electric Screwdriver

Operation instructions

Summary of Contents for CLT-50AT-RE

Page 1: ...1 CLT 50AT RE Power Controller TLF series Electric Screwdriver Operation instructions...

Page 2: ...er is grounded in use 6 When assembling or disassembling the transformer and electric driver make sure the power is OFF 7 STOP function Make sure the screw locking time to use the STOP function at a p...

Page 3: ...ry speed voltage switch may change output voltage of the electric driver by 30V 20V 3 Electric driver power cord socket please use the connection line provided by the manufacturer 4 Signal state indic...

Page 4: ...socket 2 2A 110V 1A 230V Fuse jack 2A 110V or 1A 230V 3 Output input signal terminal may control start and stop of electric driver and screw locking output signal 4 110V 230V Electric supply input sel...

Page 5: ...ower is off T2 2 Input the signal to start the electric driver at least in 2 seconds after the transformer is started T3 0 5 Indicating the start signal of the electric driver which shall exceed 0 5 s...

Page 6: ...ich is explained as follows 1 If the electric driver is rotating input of this signal may stop the rotation of the electric driver 2 Finish Open If the screw is locked the signal may open Finish outpu...

Page 7: ...C110V 0 5A DC24V1A Max Allowable Voltage 125VAC 30VDC Max Allowable Current 1A VIII Specifications Model CLT 50AT RE Size 180mm 90mm 85mm Weight 2700g Input Voltage AC 110V or 230V 50 60Hz AC Plug Cor...

Page 8: ...AP ADJ can be used at a time confirmed by the user 0 2 3 0 seconds 6 In operation each time receiving the signal from the lock brake of the screw control the SIGN light of this unit will turn on and t...

Reviews: