Hilti WSC 255-KE Operating Instructions Manual Download Page 23

18

en

used.

For the riving knife to work, it must be thicker

than the body of the blade but thinner than the tooth
set of the blade.

b)

Adjust the riving knife as described in this instruc-
tion manual.

Incorrect spacing, positioning and align-

ment can make the riving knife ineffective in pre-
venting kickback.

c)

Always use the riving knife except when plunge cut-
ting.

Riving knife must be replaced after plunge cut-

ting. Riving knife causes interference during plunge
cutting and can create kickback.

d)

For the riving knife to work, it must be engaged in
the workpiece.

The riving knife is ineffective in pre-

venting kickback during short cuts.

e)

Do not operate the saw if riving knife is bent.

Even

a light interference can slow the closing rate of a guard.

4.2 Additional safety precautions

4.2.1 Personal safety

a)

Wear ear protection.

Excessive noise may lead to a

loss of hearing.

b)

Use the auxiliary handle supplied with the tool.

Loss of control of the tool may lead to injury.

c)

Always hold the tool securely with both hands on
the grips provided. Keep the grips clean, dry and
free from oil and grease.

d)

Breathing protection must be worn when the tool is
used without a dust removal system for work that
creates dust.

e)

To avoid tripping and falling when working, always
lead the sypply cord, extension cord and dust extrac-
tion hose away tho the rear.

f)

Bring the blade into contact with the workpiece only
after the circular saw has been switched on.

g)

The area above and below the kerf must be free of
obstructions. Do not saw into screws and nails etc.

h)

Do not use the machine for sawing overhead.

i)

Do not attempt to brake the speed of the saw blade
by pressing it to the side.

j)

Do not use:

– cutting discs designed for use with an angle grinder
– hardened steel saw blades (HSS steel)

k)

Do not touch the part of the blade projecting beneath
the workpiece, the clamping flange or the flange
screw.

l)

Never press the spindle lockbutton while the blade
is rotating.

m)

Operate the tool only together with the applicable

protective devices or equipment.

n)

Wear protective gloves when changing insert tools.
The insert tool may become hot during use.

o)

Operate the tool only as directed and only when it
is in faultless condition.

p)

Exercise your fingers during pauses between work
to improve the blood circulation in your fingers.

q)

Dust from material such as paint containing lead,
some wood species, minerals and metal may be harm-
ful. Contact with or inhalation of the dust may cause

allergic reactions and/or respiratory diseases to the
operator or bystanders. Certain kinds of dust are clas-
sified as carcinogenic such as oak and beech dust
especially in conjunction with additives for wood con-
ditioning (chromate, wood preservative). Material
containing asbestos must only be treated by spe-
cialists.

Where the use of a dust extraction device is

possible it shall be used. To achieve a high level of
dust collection, use a suitable vacuum cleaner of
the type recommended by Hilti for wood dust and/or
mineral dust together with this tool. Ensure that the
workplace is well ventilated. The use of a dust mask
of filter class P2 is recommended. Follow national
requirements for the materials you want to work
with.

r)

The tool is not intended for use by children, by debil-
itated persons or those who have received no instruc-
tion or training.

s)

Children must be instructed not to play with the tool.

4.2.2 Power tool use and care

a)

Secure the workpiece. Use clamps or a vice to hold
the workpiece in place.

The workpiece is thus held

more securely than by hand and both hands remain
free to operate the tool.

b)

Ensure that the insert tools used are equipped with
the appropriate connection end system and that they
are properly fitted and secured in the chuck

.

c)

In the event of a power faillure, switch the tool off
and unplug the supply cord.

This prevents inadver-

tent starting when the power returns.

d)

Hold tool by insulated gripping surfaces when per-
forming an operation where the cutting tool may
contact hidden wiring or its own cord.

Contact with

a “live” wire will make exposed metal parts of the tool
“live” and shock the operator.

4.2.3 Electrical safety

a)

Before beginning work, check the working area (e.g.
with a metal detector) to ensure that no concealed
electric cables or gas and water pipes are present.

External metal parts of the tool may become live if,
for example, an electric cable is damaged inadvertenly.
This presents a serious risk of electric shock.

b)

Check the condition of the supply cord and its plug
connections and have it replaced by a qualified
electrician if damage is found. Check the condi-
tion of the extension cord and replace it if dam-
age is found. Do not touch the supply in the event
of it suffering damage while working. Disconnect
the supply cord plug from the socket

. Damaged

supply cords and extension cords present a risk of
electric shock.

c)

Use of a fault current protection switch increases
safety at work.

4.2.4 Work area

a)

Ensure that the workplace is well lit.

Printed: 07.07.2013 | Doc-Nr: PUB / 5071325 / 000 / 00

Summary of Contents for WSC 255-KE

Page 1: ...ctions en Mode d emploi fr Istruzioni d uso it Gebruiksaanwijzing nl Manual de instru es pt Manual de instrucciones es Brugsanvisning da K ytt ohje fi Bruksanvisning sv el WSC 255 KE WSC 265 KE Printe...

Page 2: ...1 2 11 11 3 9 9 4 4 22 23 23 10 10 17 18 19 20 21 21 6 6 7 8 15 16 5 13 12 14 1 Printed 07 07 2013 Doc Nr PUB 5071325 000 00...

Page 3: ...2 3 6 1 4 3 5 2 4 Printed 07 07 2013 Doc Nr PUB 5071325 000 00...

Page 4: ...9154 7 MultiCut W CSC 180x20 z24 HW 339156 2 QuickCut W CSC 180x20 z18 HW 339158 8 SpecialCut W CSC 180x20 z14 HW 339160 4 Bestell Bezeichnung Ordering designation R f rence Typ Type Type Artikelnumme...

Page 5: ...60 4 5 4 5 30 3 0 22 5 22 5 0 200 mm 1400 3000 mm 2 7 6 2 9 3 8 1 5 10 4 5 Printed 07 07 2013 Doc Nr PUB 5071325 000 00...

Page 6: ...255 KE WSC265 KE Handkreiss ge Aufsetzbereich der Maschine Haftstreifen Schnittkante der F hrungsschiene Handgriffaussparung Bauteile Parallelanschlag WPG255 WPG265 Zubeh r Parallelanschlag Sechskants...

Page 7: ...tem Werkst ck und sicherem Stand stattfinden Metalle d rfen nicht ges gt werden Das Ger t darf nur mit beiden H nden gef hrt zum Einsatz kommen Manipulationen oder Ver nderungen am Ger t und dessen Sc...

Page 8: ...nder verwendet werden Er eignet sich auch f r eine vorl ufige Einsch tzung der Schwingungsbelastung Der angegebene Schwingungspegel repr sentiert die haupts chlichen Anwendungen des Elektrowerkzeugs W...

Page 9: ...r unter dem Einfluss von Drogen Alkohol oder Medikamenten stehen Ein Moment der Unachtsamkeit beim Gebrauch des Ger ts kann zu ernsthaften Verletzungen f hren b Tragen Sie pers nliche Schutzausr stung...

Page 10: ...ichtigen Gr e und mit passender Aufnahmebohrung z B sternf rmig oder rund S gebl tter die nicht zu den Montageteilen der S ge passen laufen unrund und f hren zum Verlust der Kontrolle h Verwenden Sie...

Page 11: ...e Sicherheitshinweise f r alle S gen mit Spaltkeil a Verwenden Sie den f r das eingesetzte S geblatt passenden Spaltkeil Der Spaltkeil muss st rker als die Stammblattdicke des S geblatts aber d nner a...

Page 12: ...lags ausgesetzt 4 2 3 Elektrische Sicherheit a Pr fen Sie den Arbeitsbereich vor Arbeitsbeginn auf verdeckt liegende elektrische Leitungen Gas und Wasserrohre z B mit einem Metallsuchger t Aus senlieg...

Page 13: ...blattdicke dicker oder deren Schnittbreite kleiner ist als die Dicke des Spaltkeils Ungeeignete S gebl tter S gebl tter die Risse aufweisen Trennscheiben S gebl tter aus hochlegiertem Schnellarbeitsst...

Page 14: ...ntelektronik ausgestattet Die Drehzahl des S geblattes l sst sich mit dem Dreh zahlregler stufenlos von 2200 4300 U min einstellen Dabei entsprechen die Ziffern auf dem Drehzahlregler in etwa folgende...

Page 15: ...Klemmhebel eine Lasche durch deren Dr cken die Klemmhebel abgenommen wer den k nnen Setzen Sie den Klemmhebel nochmals in der beschriebenen Form auf je nach erforderlichem Klemmhub setzen Sie in der...

Page 16: ...ieren Sie ob bewegliche Ger teteile einwandfrei funktionieren und nicht klemmen ob Teile gebrochen oder so besch digt sind dass die Funktion des Ger ts beeintr chtigt ist Achten Sie darauf dass Sie nu...

Page 17: ...olle Leistung Verl ngerungskabel mit zu Verl ngerungskabel mit geringem Querschnitt ausreichendem Querschnitt einsetzen Siehe Inbetriebnahme Stellrad zur Drehzahlvorwahl Stellrad zur Drehzahlvorwahl a...

Page 18: ...TING INSTRUCTIONS WSC255 KE WSC265 KE hand held circular saw Lateral cutting angle scale up to 60 Saw positioning starting section Non slip strips Guide rail cutting edge Grip opening Parts of the WPG...

Page 19: ...ed to prevent movement and the operator must work from a secure stance Sawing metals is not permissible The tool may be operated only when held and guid ed by both hands No changes or modifications ma...

Page 20: ...cordance with a standardised test given in EN 60745 and may be used to compare one tool with another It may be used for a preliminary asses sment of exposure The declared vibration emission level repr...

Page 21: ...ugging in power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turn ing the power tool on A wrench or a key left attached to a rotating part of the power t...

Page 22: ...when interrupting a cut for any reason release the trigger and hold the saw motionless in the material until the blade comes to a complete stop Never attempt to remove the saw from the work or pull th...

Page 23: ...arm ful Contact with or inhalation of the dust may cause allergic reactions and or respiratory diseases to the operator or bystanders Certain kinds of dust are clas sified as carcinogenic such as oak...

Page 24: ...cord for damage at regular intervals Damaged extension cords must be replaced Recommended minimum cross sections and max cord lengths Conductor cross section Mains voltage 1 5 mm2 2 5 mm2 110 V 20 m...

Page 25: ...ck that the switch on the tool is in the OFF position Connect the supply cord plug to the mains socket Place the tool on a suitable surface Release the cutting depth locking lever Lift the tool by the...

Page 26: ...ase the fastening screws Adjust the riving knife as shown in the illustration 7 Accessories Guides Sawing using the parallel guide The parallel guide accessory is used to make pre cise cuts along the...

Page 27: ...cut as described above The cutting angle indicated is the angle of deviation from a straight right angled cut Plunge cutting Use two screw clamps to fasten the guide rail to the workpiece Lock the to...

Page 28: ...urfaces clean and free from oil and grease Do not use cleaning agents which contain silicone The outer casing of the tool is made from impactresis tant plastic Sections of the grip are made from a syn...

Page 29: ...rials from which Hilti power tools are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrange ments for tak...

Page 30: ...423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2530 0410 10 Pos 1 1 Printed in Liechtenstein 2010 Right of technical and programme changes reserved S E O 3...

Reviews: