background image

5

en

G

When working outdoors, use only extension cords
approved and correspondingly marked for this appli-
cation.

G

In the event of a power cut: switch the appliance off
and unplug the supply cord.

G

Avoid using extension cords with multiple sockets and
operating several appliances simultaneously.

G

Never operate the appliance when it is dirty or wet.
Dust or dampness on the surface of the appliance make
it difficult to hold and, under unfavorable conditions,
may lead to electric shocks.

G

Never spray the top section of the appliance with water.
This presents a risk of personal injury and may cause
damage to the appliance.

G

The connections used for supply cords, extension cords
or electric tool connecting cables must offer protec-
tion from sprayed water.

G

Grip the plug when unplugging the supply cord (do
not pull or tug at the supply cord).

G

Never pull the vacuum cleaner by the supply cord
when moving it to a new working position.

3.3.3 Types of dust

G

Inflammable or explosive dusts (magnesium or alu-
minium dust etc.) must not be picked up with the appli-
ance.

G

Dusts that present a health hazard must not be picked
up with the appliance.

3.3.4 Types of liquid

G

Inflammable, explosive or caustic liquids (gasoline,
solvents, acids (pH < 5), alkalies (pH > 12.5) etc.) must
not be picked up with the appliance.

G

Wear protective clothing when working with mineral-
based drilling slurry and avoid skin contact (pH > 9

¡

caustic).

3.5 Thermal hazards

G

Hot materials must not be picked up with the appli-
ance (glowing cigarettes, hot ash, etc.)

3.4 Requirements to be met by users

G

The appliance is intended for professional use.

G

The appliance may be operated, serviced and repaired
only by authorized, trained personnel. This personnel
must be informed of any special hazards that may be
encountered.

G

Always concentrate on the job you are doing. Proceed
carefully and do not use the appliance if your full atten-
tion is not on the job.

3.5 Personal protective equipment

G

Wear protective clothing when working with mineral-
based drilling slurry and avoid skin contact (pH > 9

¡

caustic).

Symbols used on the tool:

V

............................

volts

~

............................

alternating current

Hz

............................

hertz

W

............................

watts

A

............................

amperes

............................

protective grounding

4. Description

4.1 Use of the tool as directed

The VCU 40 is a universal industrial vacuum cleaner with
efficient self-cleaning filter system for dry dust. It can
be used for dry or wet vacuum cleaning applications.
The appliance is particularly suitable for removing large
quantities of mineral-based dust in conjunction with Hilti
diamond grinders, cutters, rotary hammer drills and dry-
cutting diamond coring machines.
The appliance may also be used for the suction removal
of materials in liquid form.
It is suitable for the suction removal of mineral-based
drilling slurry.
The appliance may be used for cleaning work on con-
struction sites or in workshops for wet and dry vacuum
cleaning applications.

G

The appliance must not be used to pick up explosive
substances, substances hazardous to health, glow-
ing / burning or inflammable dusts (e.g. magnesium
or aluminium dust etc.) or inflammable or caustic liq-
uids (e.g. gasoline, solvents, acids etc.).

G

The appliance must not be operated when laid down
on its side (always operate in upright position).

G

Do not use the appliance as a substitute for a ladder.

G

Do not use the appliance for continuous, stationary
operation in an automatic or semi-automatic system.

G

Manipulation or modification of the appliance is not
permissible.

G

To avoid the risk of injury, use only original Hilti acces-
sories and auxiliary equipment.

Printed: 07.07.2013 | Doc-Nr: PUB / 5071299 / 000 / 00

Summary of Contents for VCU 40

Page 1: ...VCU 40 Operating instructions en Printed 07 07 2013 Doc Nr PUB 5071299 000 00 ...

Page 2: ...1 1 9 2 7 8 3 4 6 5 This Product is Certified Ce produit est homologué Producto homologado por Este produto está registrado C US Printed 07 07 2013 Doc Nr PUB 5071299 000 00 ...

Page 3: ...2 3 4 5 1 1 1 3 2 5 4 2 AUTO MAN 0 2 1 4 3 3 2 2 AUTO MAN 0 2 Printed 07 07 2013 Doc Nr PUB 5071299 000 00 ...

Page 4: ...6 7 5 3 4 7 6 1 2 3 1 2 Printed 07 07 2013 Doc Nr PUB 5071299 000 00 ...

Page 5: ...ts 햲 Grip 햳 Accessory compartment 햴 Control switch with suction power regulation 햵 Latch 햶 Waste material container 햷 Grip for emptying container 햸 Hose socket 햹 Electric socket 햺 Supply cord stowage hook These numbers refer to the corresponding illustra tions The illustrations can be found on the fold out cover pages Keep these pages open while studying the oper ating instructions In these operat...

Page 6: ...d electric appliances must be plugged into an outlet properly installed and grounded in accordance with all codes and ordi nances Never remove the grounding prong or mod ify the plug in any way Do not use any adaptor plugs Check with a qualified electrician if you are in doubt as to whether the outlet is properly ground ed If the tools or applicances should electrically mal function or break down ...

Page 7: ... be fore making any adjustments changing acces sories or storing the tool or electric appliances Such preventive safety measures reduce the risk of starting the tool or electric appliances accidentally 5 5 Store idle tools out of reach of children and other untrained persons Tools are dangerous in the hands of untrained users 5 6 Maintain tools with care Keep cutting tools sharp and clean Properly...

Page 8: ... the appliance is not in use e g during pauses between work before maintenance and before changing the filter G Switch the appliance off before transporting it G Check the appliance for possible damage Protective devices and any parts that may have suffered slight damage should be checked for correct operation and functionality before further use of the appliance Safe ty devices or other parts tha...

Page 9: ...rained personnel This personnel must be informed of any special hazards that may be encountered G Always concentrate on the job you are doing Proceed carefully and do not use the appliance if your full atten tion is not on the job 3 5 Personal protective equipment G Wear protective clothing when working with mineral based drilling slurry and avoid skin contact pH 9 caustic Symbols used on the tool...

Page 10: ... 6 ft Supply cord type H 07 RN F 3G1 52 US SJTW A AWG 16 3 Max suction performance air 1200 W 60 l s 1100 W 50 l s Max vacuum 1200 W 23000 Pa 230 mbar 1100 W 21000 Pa 210 mbar Filter surface area 0 7 m2 7 5 sq ft Noise pressure level 60 dB A at a distance of 1 m 3 2 ft Container volume 40 l 10 6 gal Effective dust capacity 15 l 4 gal Effective water capacity 20 l 5 3 gal Suction hose 36 mm 1 4 in ...

Page 11: ...ticular A disposal bag Hilti accessory must always be fitted in the waste material container before using the appli ance to pick up dry dust The waste material collect ed can then be disposed of cleanly and easily Before picking up dry dust take care to ensure that the filter element is not damp after having previously used the vacuum cleaner to pick up liquids A damp filter element quickly become...

Page 12: ...om the hose socket 2 Grip the waste material container with one hand under its bottom edge and the other hand at its top edge 3 Empty the waste material container by tipping it NOTE The waste material must be disposed of in accordance with the applicable regulations 4 Clean the edge of the waste material container the hose socket and the hose connector 8 9 Emptying the waste material container wit...

Page 13: ...rical section of the appliance my be repaired only by trained electrical specialists Use only original Hilti accessories and spare parts Use of other parts may negatively affect safety of the appliance Do not modify the appliance in any way This could put present a safety risk 9 5 Checking after cleaning and maintenance After cleaning and maintenance check that all parts of the appliance have been...

Page 14: ...sewerage system without suitable pre treatment is problematical Ask the local authorities for information about applic able regulations We recommend the following pre treatment Allow the slurry to settle and dispose of the solid material at a construction waste disposal site the addition of a flocculent may accelerate the settling process Water from the drilling slurry alkaline ph value 7 should b...

Page 15: ... 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2837 0603 0 5 Pos 3 1 Printed in Liechtenstein 2003 Right of technical and programme changes reserved S E O 304373 Printed 07 07 2013 Doc Nr PUB 5071299 000 00 ...