background image

Page

2

Installation 

Manual 

PoleSides™

Saddle clamp

Upper bracket

Welded lower bracket

5

16

” Washers & Nuts

2

1

10 year limited Product Warranty

Unirac, Inc., warrants to the original purchaser 
(“Purchaser”) of product(s) that it manufactures 
(“Product”) at the original installation site that the 
Product shall be free from defects in material and 
workmanship for a period of ten (10) years, from the 
earlier of 1) the date the installation of the Product 
is completed, or 2) 30 days after the purchase of the 
Product by the original Purchaser. This Warranty does 
not cover damage to the Product that occurs during its 
shipment, storage, or installation.

This Warranty shall be VOID if installation of the 

Product is not performed in accordance with Unirac’s 
written installation instructions, or if the Product has 
been modified, repaired, or reworked in a manner not 
previously authorized by Unirac IN WRITING, or if 
the Product is installed in an environment for which 
it was not designed. Unirac shall not be liable for 
consequential, contingent or incidental damages arising 
out of the use of the Product by the Purchaser under 
any circumstances.  

If within the specified Warranty period the Product 
shall be reasonably proven to be defective, then Unirac 

shall repair or replace the defective Product, or any 
part thereof, in Unirac’s sole discretion. Such repair or 
replacement shall completely satisfy and discharge all of 
Unirac’s liability with respect to this limited Warranty. 
Under no circumstances shall Unirac be liable for 
special, indirect or consequential damages arising out of 
or related to use by Purchaser of the Product.

Manufacturers of related items, such as PV modules and 
flashings, may provide written warranties of their own. 
Unirac’s limited Warranty covers only its Product, and 
not any related items.

Mounting pole guidelines

The installer is solely responsible for use of the information below. 

These are general guidelines for normal installations. The following 

variances can affect your installation:

•  The required diameter and depth of the hole are dependent 

on soil type, which varies by locale. An installation in loose, 

sandy soil or clay will require larger, deeper holes and, 

therefore, more concrete than an installation in soil of average 

density.

•  The depth and width of the hole should also be increased in 

areas subject to winds in excess of 90 mph, particularly if the 

location of the mounting pole is open and unprotected.

•  Poles taller than 6 feet above ground require that the depth of 

the hole be increased.

If in doubt, consult a professional civil engineer who is familiar with local 

soil conditions and wind load requirements.

  1.  Stand the pipe in the hole. Brace the pole so that it is plumb. 

Pour concrete around the pipe, filling the hole to ground 

level.  Add an inch or two of extra concrete above the hole. 

Use a trowel to slope the concrete around the pole.

  2.  Allow the concrete to set up for at least 24 hours before 

installing your PoleSide™ rack.

Assembly

Lay module face down on a suitable surface. Slide the ¼” hex bolts 

into the slot on the upper and lower brackets. Center the bolts in the 

slot at the same distance as the module mounting holes. Attach the 

brackets to the module taking into account the two bumps on the 

bracket. Loosely fasten the ¼” nuts to the bolts. Center the upper and 

lower brackets with respect to the module and tighten the nuts.
Mount the rack and module to the pole with the u-bolts, clamps, 5⁄16” 

washers and nuts. 
Ensure the panel is facing south and then tighten the 5⁄16”  nuts.

Upper bracket

Bumps

Welded Lower bracket

Bumps

1

2

Please be advised that rack numbers (401260,401264, 
401274, 401276 and 401278) are 45˚ mounts and should 
be mounted on the pole with the two bumps on the rails 
facing up and rack numbers (401262, 401266, 401275, 
401272 and 401279) are 60˚ mounts and should be 
mounted with the two bumps on the rails facing down. 