background image

a dry brush. Do not permit foreign objects to enter the

interior of the power tool. Clean the outside of the power

tool at regular intervals with a slightly damp cloth. Do

not use a spray, steam pressure cleaning equipment or

running water for cleaning. This may negatively affect the

electrical safety of the power tool.

8.3 Cleaning or replacing the dust shield

Clean the dust shield on the chuck with a dry, clean

cloth at regular intervals. Clean the sealing lip by wiping it

carefully and then grease it again lightly with Hilti grease.

It is essential that the dust shield is replaced if the sealing

lip is found to be damaged. Push the tip of a screwdriver

under the edge of the dust shield and prise it out toward

the front. Clean the area of the chuck in contact with dust

shield and then fit a new dust shield. Press it in firmly

until it engages.

8.4 Care of the Li-ion battery

Avoid entrance of moisture.

Charge the battery fully before using it for the first time.

In order to achieve maximum battery life, stop discharging

the battery as soon as a significant drop in performance

is noticed.

NOTE

If use of the power tool continues, further battery dis-

charge will be stopped automatically before the battery

cells suffer damage.

Charge the battery with the Hilti charger approved for use

with Li-ion batteries.

NOTE

- A conditioning charge (as is required with NiCd or

NiMH batteries) is not necessary.

- Interruption of the charging procedure has no negative

effect on battery life.

- Charging can be started at any time with no negative

effect on battery life. There is no memory effect (as

with NiCd or NiMH batteries).

- For best results, batteries should be stored fully

charged in a cool dry place. Avoid charging the battery

in places subject to high ambient temperatures (e.g. at

a window) as this has an adverse effect on battery life

and increases the rate of self-discharge.

- If the battery no longer reaches full charge, it may

have lost capacity due to aging or overstressing. It

is possible to continue working with a battery in this

condition but it should be replaced in good time.

8.5 Maintenance

WARNING

Repairs to the electrical section of the power tool may

be carried out only by trained electrical specialists.

Check all external parts of the power tool for damage

at regular intervals and check that all controls operate

faultlessly. Do not operate the power tool if parts are

damaged or when the controls do not function faultlessly.

If necessary, the power tool should be repaired by Hilti

Service.

8.6 Checking the power tool after care and

maintenance

After carrying out care and maintenance work on the

power tool, check that all protective and safety devices

are fitted and that they function faultlessly.

9 Troubleshooting

Fault

Possible cause

Remedy

The power tool doesn’t run.

The battery is discharged or fitted

incorrectly.

The battery must be heard to engage

with a double click or, respectively,

needs to be charged.

Electrical fault.

Remove the battery from the power

tool and contact Hilti Service.

The battery is too hot or too cold.

Bring the battery to the

recommended working temperature.

The power tool doesn’t run and

1 LED blinks.

The battery is discharged.

Change the battery and recharge the

discharged battery.

The battery is too hot or too cold.

Bring the battery to the

recommended working temperature.

The tool doesn’t work and all 4

LEDs blink.

The power tool has been overloaded.

Release the control switch and press

it again.

The overheating prevention cut-out

has been activated.

Allow the power tool to cool down.

Clean the ventilation slots.

en

11

Printed: 07.07.2013 | Doc-Nr: PUB / 5140928 / 000 / 00

Summary of Contents for TE 2-A18

Page 1: ...2023935 2023935 TE 2 A18 Operating instructions en Mode d emploi fr Manual de instrucciones es Manual de instru es pt Printed 07 07 2013 Doc Nr PUB 5140928 000 00...

Page 2: ...1 This Product is Certified Ce produit est homologu Producto homologado por Este produto est registrado C US Printed 07 07 2013 Doc Nr PUB 5140928 000 00...

Page 3: ...4 6 3 2 Printed 07 07 2013 Doc Nr PUB 5140928 000 00...

Page 4: ...7 10 8 9 Printed 07 07 2013 Doc Nr PUB 5140928 000 00...

Page 5: ...er ating instructions In these operating instructions the designation the power tool always refers to the TE 2 A18 cordless rotary hammer Components operating controls and indicators 1 Chuck Function...

Page 6: ...y and for driving in and removing screws Use only the batteries and chargers recommended by Hilti The power tool may be used only in a dry environment Do not use the power tool where there is a risk o...

Page 7: ...ve spindle will not rotate even when the control switch is pressed fully The power tool can be used again as soon as the temperature is within the permissible range 2 7 Lubrication Permanent lubricati...

Page 8: ...S Charger for Li ion batteries C 4 36 ACS TPS Battery B 18 3 3 Li Ion Battery B 18 2 6 Li ion Battery B 18 1 6 Li Ion 4 Technical data Right of technical changes reserved Power tool TE 2 A18 Rated vol...

Page 9: ...ble for outdoor use reduces the risk of electric shock f If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of an RCD reduces the risk o...

Page 10: ...ctric shock 5 3 Additional safety precautions 5 3 1 Personal safety a Always hold the power tool securely with both hands on the grips provided Keep the grips dry clean and free from oil and grease b...

Page 11: ...the power tool Short circuiting the bat tery terminals presents a risk of fire explosion and chemical burns i Avoid ingress of dampness Dampness may cause a short circuit resulting in a risk of burni...

Page 12: ...the battery pack when removing it After removal check the battery pack and the power tool 1 Press both battery release buttons 2 Pull the battery out of the power tool toward the rear 6 5 Transport an...

Page 13: ...xceeding 180 mm 7 in length DANGER Check that the side handle is correctly secured in place An insufficiently secured side handle may cause personal injury 1 Release the side grip clamping band by tur...

Page 14: ...imum rate of drilling progress 9 Reduce drilling speed shortly before breaking through in order to avoid spalling 7 2 5 Reading the charge status LED display on Li ion batteries 10 NOTE The charge sta...

Page 15: ...ry place Avoid charging the battery in places subject to high ambient temperatures e g at a window as this has an adverse effect on battery life and increases the rate of self discharge If the battery...

Page 16: ...the battery engages securely Contact Hilti Service if the problem persists The power tool or the battery gets very warm Electrical fault Switch the power tool off immedi ately remove the battery and...

Page 17: ...used in the tool This warranty provides the free of charge repair or re placement of defective parts only over the entire lifespan of the tool Parts requiring repair or replacement as a result of nor...

Page 18: ...Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 4118 0413 00 Pos 3 1 Printed in China 2013 Right of technical and programme changes reserved S E O 20239...

Reviews: