20 English
Malfunction
Possible cause
Action to be taken
The symbol indicat-
ing “Hardware fault”
is displayed.
A hardware fault has
been identified.
▶
Connect the torque
module to a PC.
▶
Use the
PROFIS Adaptive
Torque
software to
read out fault memory
and follow the soft-
ware's troubleshoot-
ing instructions.
The symbol indicat-
ing “Documenta-
tion function deacti-
vated” is displayed.
Documentation function
deactivated (warning
only).
▶
If you require the doc-
umentation function,
connect the torque
module to the PC and
activate the documen-
tation function in the
PC software
PROFIS Adaptive
Torque
.
▶
Where applicable,
press the OK button
to hide the message
and continue the
starting process for
the torque module.
The symbol indicat-
ing “...% of mem-
ory is in use” is dis-
played. (The symbol
appears when the
value is ≥ 90 %.)
Usage of data memory
in the module is indi-
cated in percent.
Note:
When 100 % is reached,
the oldest data will be
overwritten!
▶
Connect the torque
module to a PC.
▶
Use the
PROFIS Adaptive
Torque
software to
read out the data
so that they can be
documented in a
report.
▶
Subsequently delete
the data in the torque
module data memory
in order to clear the
memory for further
use.
Printed: 15.09.2017 | Doc-Nr: PUB / 5331629 / 000 / 02
Summary of Contents for SI-AT-A22
Page 2: ...1 Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...
Page 3: ...2 3 4 Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...
Page 4: ...5 6 7 Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...
Page 5: ...8 Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...
Page 350: ...Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...
Page 351: ...Printed 15 09 2017 Doc Nr PUB 5331629 000 02 ...