S-BT-ER, S-BT-EF
08/2018
215
www.hilti.group
Edge distance:
Type A connector: ≥ 6 mm [0.236”]
Type B connector: ≥ 20 mm [0.787”]
The installation temperature is the temperature at which the S-BT studs are
installed. A distinction is made between the temperature of the base material and
the temperature of the S-BT studs, drilling and installation tools and accessories
The installation temperature range can be found in the table below.
The service temperature is the temperature at which the S-BT studs operate.
The S-BT studs will operate effectively and without any loss in performance
(loads, sealing function, etc.) within the specified service temperature range.
Outside this temperature range the S-BT studs may fail.
Note:
The service temperature range of the connected cable lugs and cables has to
be observed. For details please contact the supplier of the cable lugs and cables.
When using Hilti S-BT fasteners in combination with fire rated boundaries in
Shipbuilding facilities, the max. service temperature for a period of 60 minutes
is higher. For more details refer to section 5.10 “Fire resistance” in the S-BT
Specification binder.
Spacing:
Type A connector: ≥ 22 mm [0.866”]
Type B connector: ≥ 40 mm [1.575”]
Spacing & edge distances
Installation temperature and service temperature
≥
20
[0.787"]
≥
40
[1.575"]
≥
6
[0.236"]
≥
6
[0.236"]
≥
22
[0.866"]
≥
22
[0.866"]
≥
20
[0.787"]
Designation
Installation temperature
Service temperature
min
max
min
max
Base material
-40 °C
+60 °C
-40 °C
+100 °C
S-BT studs
-10 °C
+60 °C
-40 °C
+100 °C
Drilling & Installation
tools and accessories
-10 °C
+60 °C
n.a.
n.a.