background image

3

en

6. Cold weather (40°F for colder) operation

6.1 Warm up the tool

If possible, store the tool overnight in a warm place.

OR - set the tool in a warm spot such as in a warm
vehicle. NEVER expose the tool to an open flame.

OR - Free-fire the tool (shoot without fasteners) at a
pressure of 25 PSI to gradually warm up moving parts.
NEVER free-fire the tool at high pressure.

6.2 Use a suitable lubricant

“Kilfrost”, a special lubricant that prevents moisture
buildup and ice formation in cold weather, is available
from your Hilti Representative.

7. Preventive Maintenance

The maintenance schedule required for your tool will
vary with such factors as amount of use, storage con-
ditions, air quality, humidity, and outside temperature.
It is important for each user to establish and maintain a
schedule based upon his usage.

-CAUTION-

when cleaning:

Never use grease for the maintenance/lubrication of
parts of the tool. This may lead to malfunctions. Use
only Hilti lubricant spray or a product of comparable
quality.
The residues deposited inside tools contain substances
that may be injurious to your health:
– Do not inhale any dust or dirt while cleaning.
– Keep the dust or dirt away from foodstuffs.
– Wash your hands after cleaning the tool.

7.1 Cleaning

Disassemble the tool monthly and wash away sludge
and dirt with kerosene to keep the tool operating effi-
ciently; be certain to re-lubricate the 0-rings with spe-
cial 0-ring lubricant (Hilti item no 12423) and re-oil the
tool after each clean ing. NEVER use Diesel fuel or flam-
mable cleaning solvents to clean the tool.

7.2 Daily lubrication

Follow the “Lubricate The Tool” instructions under Tool
Set-up and Operation.

7.3 Bumper

Check for surface deterioration monthly. Discoloration
is first sign of wear.

7.4 Inspection

Daily inspect screws and nuts on tool. Tighten any which
may have loosened during operation.

7.5 0-ring

Check monthly for deterioration. If an 0-ring appears
worn, replace it, along with the others in that assembly.
Lubricate the replacement 0-rings with special 0-ring
grease (Hilti item no 12423) before reassembling the
tool.

7.6 Safety yoke

Inspect daily to ensure that the safety mechanism is
operating properly and that it is not binding from wood
particles, sawdust and other debris.

7.7 Compressor

Maintain in accordance with manufacturer’s recom-
mendations. NEVER operate a compressor at pressures
or speeds in excess of those recommended by the man-
ufacturer.

7.8 Compressor air filters

Clean or replace compressor air filter cartridge regularly.

7.9 Eliminate air line moisture

By draining the compressor storage tank daily in those
areas with high relative humidity.
By using an air line moisture filter and emptying it fre-
quently.
By avoiding the use of an excessive number of connec-
tions in long air lines.

8. Replacement Parts and Repair Service

Your Hilti air tool is precision engineered for safety and
durability. NEVER attempt to modify parts, since this
can compromise the built-in safety and shorten the life
of the tool.

When servicing, use only identical Hilti replacement
parts. Replacement parts shown on the parts list are
available through your local Hilti representative or by
calling Customer Service at 1-800-879-8000.

Hilti operates a nationwide network of Repair Centers,
and rapid service is a hallmark of the Hilti system. If your
tool requires service or warranty repairs, contact your
local Hilti Representative or Customer Service at 1-800-
879-8000.

8.1 Tools needed for R4X12 S service

4 mm AIIen Wrench

5 mm Allen Wrench

Printed: 07.07.2013 | Doc-Nr: PUB / 5070503 / 000 / 00

Summary of Contents for R4X12 S

Page 1: ...R4X12 S Operating instructions en Mode d emploi fr Manual de instrucciones es Printed 07 07 2013 Doc Nr PUB 5070503 000 00 ...

Page 2: ...GH SHEAR NAIL Base Material Thickness 3 16 3 8 X EDNK22 THQ12MX HIGH SHEAR NAIL Base Material Thickness 1 8 1 4 X ZF 22THS12M temporary fastenings Base Material Thickness 1 8 1 4 Printed 07 07 2013 Doc Nr PUB 5070503 000 00 ...

Page 3: ...3 4 Printed 07 07 2013 Doc Nr PUB 5070503 000 00 ...

Page 4: ...tay in balance at all times NEVER carry the tool with the trigger depressed DO NOT use oxygen combustible gases or high pres sure compressed gas tanks as the air supply for the tool ALWAYS use authentic Hilti R4X12 S fasteners and parts in your tool SAFETY equipment such as safety glasses hearing pro tection and hard hat should ALWAYS be worn by the operator and bystanders when the tool is in use ...

Page 5: ...o the tool before loading fasteners into magazine 1 Pull the pusher fully back wards until it is held in place by the pusher latch pin Open the flap on the maga zine all the way up 2 Insert the strips of nails into the magazine and slide all the way forward The nail strips should be insert ed parallel to the magazine 3 Close the flap fully Holding the pusher firmly release it from the magazine cat...

Page 6: ...urface deterioration monthly Discoloration is first sign of wear 7 4 Inspection Daily inspect screws and nuts on tool Tighten any which may have loosened during operation 7 5 0 ring Check monthly for deterioration If an 0 ring appears worn replace it along with the others in that assembly Lubricate the replacement 0 rings with special 0 ring grease Hilti item no 12423 before reassembling the tool ...

Page 7: ... Fastener Skipping Air Pressure too low Increase air pressure to the minimum required to eliminate skipping Max 175 PSI Incorrect lubrication Refer to setup instructions for proper cleaning and lubrication Obstruction in nosepiece 8 Clear obstruction using nylon brush or compressed air Contact your Hilti Representative Pusher 47 not moving freely or Check for easy movement Clean or replace nails j...

Page 8: ...dy 56 Replace trigger valve body assy 10 Instructions for disassembly of R4X12 S Use with Exploded View Drawings 2 4 and Parts list NOTE Before starting on the disassembly of the tool disconnect the tool from the air supply and remove all fasteners from the magazine assembly If handle grip 40 plate 46 flange 10 and valve bushings 52 59 require service contact your Hilti Representative 10 1 Magazin...

Page 9: ... squeeze the 0 ring across its outside diam eter between your thumb and index finger Now push outward on the 0 ring with your thumb and index finger until the 0 ring forms a loop Once the loop is formed hold onto the 0 ring and part with one hand and then roll the 0 ring out of the groove with the oth er hand When working with small diameter 0 rings using a pencil point or an 0 ring pick to get ho...

Page 10: ...holes in grip and pusher Secure both pieces with spring pin 62 using a 2 mm pin punch Make sure pin 62 is flush with top and bottom of pusher 11 10 Magazine assembly 48 Safety valve piston safety yoke pusher and grip assem bled see 11 7 11 8 and 11 9 Insert magazine assem bly 48 as far as it will go in nosepiece 8 Secure 2 hex socket screws 29 washers 61 and locknuts 66 with 17 mm fork wrench and ...

Page 11: ...e of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instructions and the technical sys tem is maintained This means that only original Hilti consumables components and spare parts may be used in the tool This warranty provides the free of charge repair or repla...

Page 12: ... 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3007 0604 00 Pos 1 1 Printed in Liechtenstein 2004 Right of technical and programme changes reserved S E O 284628 A Printed 07 07 2013 Doc Nr PUB 5070503 000 00 ...

Reviews: