4 Technical data
Right of technical changes reserved.
Range of the points
30 m (98 ft)
Range of the lines and intersection point
10 m (30 ft)
Accuracy
1
±2 mm at 10 m (±0.08 in at 33 ft)
Self-leveling time
3 s
Laser class
Class 2, visible, 635 nm, ±10 nm (IEC/EN
60825-1:2007); Class II (CFR 21 §1040 (FDA)
Beam diameter
Distance 5 m: < 4 mm
Distance 20 m: < 16 mm
Line width
Distance 5 m: < 2.2 mm
Self-leveling range
±5° (typical)
Automatic power-off
Activated after: 15 min
Operating status indicator
LED and laser beams
Power supply
AA‑size batteries, Alkaline batteries: 4
Battery life (2 points and 1 line)
Alkaline battery 2,500 mAh, Tempe25°C
(+77°F): 20 h (Typical)
Operating temperature range
Min. -10°C / Max. +50°C (+14 to 122°F)
Storage temperature
Min. -25°C / Max. +63°C (-13 to 145°F)
Dust and water spray protection (except battery com-
partment)
IP 54 as per IEC 60529
Tripod thread (tool)
UNC¹⁄₄"
Tripod thread (foot)
BSW 5/8 "UNC¹⁄₄"
Weight
with the foot but without batteries: 0.413 kg ( 0.911 lbs)
Dimensions
with the foot: 140 mm X 73 mm X 107 mm
without the foot: 96 mm X 65 mm X 107 mm
1 Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810F).
5 Safety instructions
In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.1 General safety instructions
a)
Check the accuracy of the tool before using it to
take measurements.
b)
The tool and its ancillary equipment may present
hazards when used incorrectly by untrained per-
sonnel or when used not as directed.
c)
To avoid the risk of injury, use only genuine Hilti
accessories and additional equipment.
d)
Modification of the tool is not permissible.
e)
Observe the information printed in the operat-
ing instructions concerning operation, care and
maintenance.
f)
Do not render safety devices ineffective and do
not remove information and warning notices.
g)
Keep laser tools out of reach of children.
h)
Take the influences of the surrounding area into
account. Do not expose the tool to rain or snow
and do not use it in damp or wet conditions. Do
not use the tool where there is a risk of fire or
explosion.
i)
Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at a
Hilti service center.
j)
The user must check the accuracy of the tool
after it has been dropped or subjected to other
mechanical stresses.
k)
When the tool is brought into a warm environment
from very cold conditions, or vice-versa, allow it
to become acclimatized before use.
l)
If mounting on an adapter, check that the tool is
screwed on securely.
m)
Keep the laser exit aperture clean to avoid meas-
urement errors.
n)
Although the tool is designed for the tough condi-
tions of jobsite use, as with other optical and elec-
en
14
Summary of Contents for PMC 46
Page 2: ...1...
Page 3: ...2 3 4 5 6 7 8...
Page 4: ...9 10...
Page 6: ...T2 T1 Pos 2 Pos 1 2m 90 2 5m 2 5m 16...
Page 86: ...10 Hilti Hilti Hilti 11 HILTI el 80...
Page 95: ...ISO 900X 9 10 EU ja 89...
Page 122: ...Hilti Hilti 10 Hilti Hilti Hilti 11 HILTI ar 116...
Page 133: ...410556 410556 Hilti registered trademark of Hilti Corp Schaan Pos 1 20210223...