![Hilti NURON NCR 120-22 Original Operating Instructions Download Page 13](http://html1.mh-extra.com/html/hilti/nuron-ncr-120-22/nuron-ncr-120-22_original-operating-instructions_2135089013.webp)
*2321722*
2321722
English
9
5.1
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 6
5.2
Inserting the battery
WARNING
Risk of injury by short circuit or falling battery!
▶
Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶
Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the product until it engages with an audible click.
3. Check that the battery is seated securely.
5.3
Removing the battery
1. Press the battery release button.
2. Remove the battery from the product.
5.4
Switching starting lock on/off
The crimping tool has a starting lock that can be optionally activated or deactivated. If the starting lock
is activated, the control switch has to be pressed twice to start the crimping operation. This prevents
inadvertent starting.
The factory default is starting lock deactivated.
1. Remove the battery. → page 9
2. Press and hold down the control switch.
3. Insert the battery into the crimping tool.
4. Release the control switch.
▶
The green LED flashes twice; acoustic signal sounds twice: starting lock activated
▶
The green LED flashes twice; acoustic signal sounds once: starting lock deactivated
5.5
Inserting crimping die
WARNING
Risk of injury!
Unintentional starting.
▶
Remove the battery before inserting, changing or removing crimping dies.
Never operate the product without a crimping die installed!
1. Select suitable crimping dies.
2. Turn the crimping head so that the mount for the crimping dies is easily accessible.
3. Push the crimping dies in until they engage.
5.6
Removing crimping die
WARNING
Risk of injury!
Unintentional starting.
▶
Remove the battery before inserting, changing or removing crimping dies.
1. Turn the crimping head so that the mount for the crimping dies is easily accessible.
Summary of Contents for NURON NCR 120-22
Page 1: ...NCR 120 22 NCR 120C 22 English 1 Fran ais 13 Espa ol 27 Portugu s 41...
Page 2: ...1...
Page 3: ...2 3 4 5...
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ...Hilti registered trademark of Hilti Corp Schaan Pos 3 20220111 2321722 2321722...