![Hilti HIT-CT 1 Instructions For Use Manual Download Page 21](http://html1.mh-extra.com/html/hilti/hit-ct-1/hit-ct-1_instructions-for-use-manual_2136455021.webp)
Hilti HIT-CT 1
21
Product Information
– Always keep these instructions together with the product even when given to other persons.
– Check expiration date: See imprint on foil pack manifold (month/year). Do not use expired product.
– Foil pack temperature during usage: 5 °C to 40 °C / 41 °F to 104 °F.
– Base material temperature at time of installation: -5 °C to 40 °C / 23 °F to 104 °F.
– Conditions for transport and storage: Keep in a cool, dry and dark place between 5 °C and 25 °C
/ 41 °F and 77 °F.
– For any application not covered by this document / beyond values specified, please contact Hilti.
– Partly used foil packs must be used up within 4 weeks. Leave the mixer attached on the foil pack
manifold and store under the recommended storage conditions. If reused, attach a new mixer and
discard the initial quantity of anchor adhesive. A new mixer must be used for each new foil pack.
WARNING
Improper handling may cause mortar splashes.
– We recommend to wear safety glasses, gloves and protective clothes during installation.
– Never start dispensing without a mixer properly screwed on.
– Attach a new mixer prior to dispensing a new foil pack (ensure snug fit).
– Use only the type of mixer supplied with the adhesive. Do not modify the mixer in any way.
– Never use damaged foil packs and/or damaged or unclean foil pack holders (cassettes).
Poor load values / potential failure of fastening points due to inadequate borehole cleaning.
– Hilti hollow drill bits TE-CD, TE-YD must be used in conjunction with a properly maintained
Hilti vacuum cleaner with model and suction capacity (volumetric flow rate) as specified in the
accessory table.
– The boreholes must be free of debris, dust, water, ice, oil, grease and other contaminants prior
to adhesive injection.
– For blowing out the borehole - blow out with oil free air untilreturn air stream is free of noticeable
dust.
– Important! Remove all water from the borehole and blow out with oil free compressed air until
borehole is completely dried before mortar injection.
– For brushing the borehole – only use specified wire brush. The brush must resist insertion into
the borehole – if not the brush is too small and must be replaced.
Ensure that boreholes are filled from the back of the borehole without forming air voids.
– If necessary use the accessories / extensions to reach the back of the borehole.
– For overhead applications use the overhead accessories HIT-SZ / IP and take special care
when inserting the fastening element. Excess adhesive may be forced out of the borehole.
Make sure that no mortar drips onto the installer.
– If a new mixer is installed onto a previously-opened foil pack, the first trigger pulls must be
discarded.
– In water saturated concrete it is required to set the anchor immediately after cleaning the
borehole.
Not adhering to these setting instructions can result in failure of fastening points!
en
de
fr
it
nl
es
pt
da
no
sv
fi
pl
sk
cs
sl
li
lv
et
ru
zh
ko
jp
Summary of Contents for HIT-CT 1
Page 14: ...14 A C 16 18 19 5 HAS U HIT V d0 12 18 mm hef 80 192mm d0 hef TE CD TE YD 1 8...
Page 15: ...15...
Page 19: ...19 9 10 9 10 8 8 twork twork tcure 9 tcure 9 9 9 Tmax 6...
Page 60: ...Hilti HIT CT 1 60...
Page 61: ...Hilti HIT CT 1 61...
Page 62: ...Hilti HIT CT 1 62...
Page 63: ...Hilti HIT CT 1 63...