18
English
2241313
*2241313*
5.2
Inserting the battery
CAUTION
Risk of injury by short circuit or falling battery!
▶
Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶
Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the battery holder until it engages with an audible click.
3. Check that the battery is seated securely.
5.3
Removing the battery
1. Press the battery release buttons.
2. Remove the battery from the tool.
5.4
Fitting the side handle
▶
Screw the side handle into the threaded socket.
5.5
Fitting an abrasive belt
CAUTION
Risk of injury!
The abrasive belt can easily tear if the direction of travel is incorrect.
▶
Be sure to install the abrasive belt right way round for the direction of travel. The belt's direction of travel
must match the direction-of-travel arrow on the gear head.
1. Remove the side handle.
2. Swing the housing cover aside.
3. Turn the eccentric screw until it engages. This relieves the tension on the file arm.
4. Center the abrasive belt on the file arm and the drive roller.
5. Release the eccentric screw to tension the file arm.
6. Swing the housing cover back into position in front of the housing.
7. Fit the side handle. → page 18
Not every abrasive belt matches every file arm. Select the correct combination from the table
below and change the file arm if necessary → page 19.
5.5.1 Recommended combination for file arm / belt width
9 mm roller, peaked
4 mm … 9 mm
9 mm roller, crowned
4 mm … 13 mm
30 mm roller, small
13 mm … 30 mm
30 mm roller, large
13 mm … 30 mm
5.6
Adjusting the belt run
1. Adjust the belt run by turning the adjusting screw on the file arm.
2. Select the setting that keeps the belt running centered on the contact roller.
3. Set the speed. → page 19
4. Run the belt at the slowest speed and check your setting.
5.7
Removing the abrasive belt
1. Remove the side handle.
2. Swing the housing cover aside.
3. Turn the eccentric screw until it engages. This relieves the tension on the file arm.
4. Remove the abrasive belt.
5. Slacken the eccentric screw to relieve the tension on the spring of the file arm.
Summary of Contents for GFB 6X-A22
Page 2: ...1...
Page 3: ...2 3 4 5...
Page 4: ...6 7...
Page 6: ......
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ...Hilti registered trademark of Hilti Corp Schaan Pos 1 20191021 2241313 2241313...