![Hilti DD110-D Operating Instructions Manual Download Page 6](http://html.mh-extra.com/html/hilti/dd110-d/dd110-d_operating-instructions-manual_2135262006.webp)
2.2 Use of the system with various items of equipment
Type of hole drilled
Core bit diameters
Drilling direction
Material
Through-holes
16…162 mm
(⁵⁄₈"...6¹⁄₂")
All directions
Masonry (e.g. sand-
lime block, brick)
Blind holes / socket cutting
16…162 mm
(⁵⁄₈"...6¹⁄₂")
All directions
Masonry (e.g. sand-
lime block, brick)
2.3 Gears and corresponding core bit diameters
Gear
PCM core bits
HDM core bits
Speed under no load
1
42…162 mm
(1⁵⁄₈" ... 6¹⁄₂")
102…162 mm
(4" ... 6¹⁄₂")
650/min
2
16…87 mm
(⁵⁄₈" ... 3¹⁄₂")
1,380/min
2.4 TPS theft protection system (optional)
The machine may be optionally equipped with the TPS theft protection system. If equipped with this feature, the
machine can be unlocked and made ready for operation only through use of the corresponding TPS key.
2.5 The items supplied as standard include:
1 Power tool with side handle and chuck
1 Operating instructions
1 Hilti toolbox or cardboard box
2.6 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate gauge.
Recommended minimum conductor cross section and max. cable lengths
Conductor cross section
1.5 mm²
2 mm²
2.5 mm²
3.5 mm²
Mains voltage 100V
Not recommen-
ded
Not recommen-
ded
Not recommen-
ded
40 m
Mains voltage 110-120 V
Not recommen-
ded
Not recommen-
ded
30 m
Mains voltage 220-240 V
30 m
50 m
Do not use extension cords with 1.25 mm² conductors. Always use extension cords with an earth/ground conductor
for machines equipped with a PRCD.
2.7 Using a generator or transformer
This machine may be powered by a generator or transformer when the following conditions are fulfilled: The unit must
provide a power output in watts of at least twice the value printed on the type identification plate on the machine. The
operating voltage must remain 5% and -15% of the rated voltage at all times, frequency must be in the 50 – 60
Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and starting boost.
NOTE
Switching other machines or appliances on and off can cause undervoltage and/or overvoltage peaks which could
damage the machine. Never operate other machines from the generator/transformer at the same time.
en
3