Operating instructions 

en

Mode d’emploi 

fr

Manual de instrucciones 

es

Manual de instruções 

pt

Printed: 02.04.2014 | Doc-Nr: PUB / 5169300 / 000 / 01

Summary of Contents for AG 700-14D

Page 1: ... 2075441 2075441 AG 700 14D Operating instructions en Mode d emploi fr Manual de instrucciones es Manual de instruções pt Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 2: ...ꙣ ꙤꙤ ꙥ ꙧ Ꙩ ꙮ Ꙭ ꙭ Ꙫ ꙩ ꙫ Ꙧ 1 This Product is Listed Ce produit est homologué Producto homologado por Este produto está registrado Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 3: ...2 3 4 Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 4: ... 7 5 PP PP 6 Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 5: ...s the designation the power tool always refers to the AG 700 14D angle grinder Parts operating controls and indicators 1 Drive spindle lockbutton Steadying rib On off switch Safety interlock Side handle Threaded bushing for grip Spindle Keyed locating lug Clamping lever Clamping flange Clamping nut Adjusting screw Guard Abrasive cutting disc abrasive grinding disc Wrench 1 General information 1 1 ...

Page 6: ...tion conversion or new construction The power tool may be operated only when connected to a power supply providing a voltage and frequency in compliance with the information given on its type identification plate Working with metals Cutting grinding Working with mineral materials Cutting slitting and grinding Use only discs abrasive grinding discs abrasive cutting discs etc that are approved for u...

Page 7: ...cord for damage at regular intervals Replace damaged extension cords Recommended minimum conductor cross section and max cord lengths Conductor cross section 14 AWG 12 AWG 10 AWG Mains voltage 110 120 V 50 ft 100 ft 150 ft Do not use extension cords with 16 AWG conductor cross section 2 6 Using extension cords outdoors When working outdoors use only extension cords that are approved and correspond...

Page 8: ...AF D AN D DG CW DC D Guard X X X X Guard with cover plate X X Side handle X X X X X X Clamping nut not for use with ac cessories with in tegrated thread X X X X X X Clamping flange not for use with accessories with integrated thread X X X X X X 4 Technical data Right of technical changes reserved Power tool AG 700 14D Rated power input 120 V Rated current input 15 A Rated frequency 60 Hz Rated spe...

Page 9: ...ropriate conditions will reduce personal injuries c Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turn ing the power tool on...

Page 10: ...s opera tions The dust mask or respirator must be capable of filtrating particles generated by your operation Pro longed exposure to high intensity noise may cause hearing loss i Keep bystanders a safe distance away from work area Anyone entering the work area must wear personal protective equipment Fragments of workpiece or of a broken accessory may fly away and cause injury beyond immediate area...

Page 11: ...ur body in line with and behind the rotating wheel When the wheel at the point of operation is moving away from your body the possible kickback may propel the spinning wheel and the power tool directly at you c When wheel is binding or when interrupting a cut for any reason switch off the power tool and hold the power tool motionless until the wheel comes to a complete stop Never attempt to remove...

Page 12: ...aled electric cables or gas and water pipes are present External metal parts of the power tool may become live for example when an electric cable is damaged accidentally This presents a serious risk of electric shock b Check the power tool s supply cord at regular intervals and have it replaced by a qualified spe cialist if found to be damaged If the power tool s supply cord is damaged it must be ...

Page 13: ...5 To remove the guard from the power tool follow the instructions for fitting the guard but carry out the steps in the reverse order 6 2 2 Adjusting the guard or guard with cover plate 4 1 Release the clamping lever 2 Rotate the guard to the desired position 3 Close the clamping lever 6 3 Fitting and removing the disc 5 6 CAUTION Wear gloves when fitting or removing parts when making adjustments o...

Page 14: ...N The insert tool may get hot during use Wear protective gloves when changing insert tools CAUTION In accordance with the applications for which it is de signed the power tool produces a high torque Always use the side handle and hold the power tool with both hands The user must be prepared for sudden sticking and stalling of the insert tool CAUTION Working on the material may cause it to splinter...

Page 15: ... the elec trical safety of the tool Always keep the grip surfaces of the tool free from oil and grease Do not use cleaning agents which contain silicone NOTE Frequent work on conductive materials e g metal car bon fiber may make shorter maintenance intervals nec essary Take your individual work place risk assessment into account 8 2 Maintenance WARNING Do not operate the power tool if parts are da...

Page 16: ... may be used in the tool This warranty provides the free of charge repair or re placement of defective parts only over the entire lifespan of the tool Parts requiring repair or replacement as a result of normal wear and tear are not covered by this warranty Additional claims are excluded unless stringent na tional rules prohibit such exclusion In particular Hilti is not obligated for direct indire...