Requirements
28/75
4
Requirements
Technical requirements
·
The netHOST device is to be mounted on a DIN rail according to DIN
EN 60715.
·
A suitable external power supply is required.
·
The voltage to be applied must be in the allowed range 24 V ± 6 V DC.
·
The power supply must be able to deliver at least a current of 130 mA at
24 V.
·
Power supply is to be connected at the X1 connector located on the
upper side of the device (see section
Positions of the LEDs, connectors
Device Destruction by Exceeding Allowed Supply Voltage!
The voltage must not exceed 30 V, otherwise the device may be destroyed
or damaged.
In order to avoid damage caused by overheating or freezing, it is necessary
that the temperature of the device does not exceed the limits of the allowed
temperature range. For the allowed temperature, see section
General requirements
Additionally, the following preconditions must be met in order to operate the
netHOST device successfully:
·
If you are using an
NHST-T100-EN
netHOST device (order no.
1890.800) you must download the firmware to the device before
commissioning/configuring the netHOST.
·
An IP address must be assigned to the netHOST device
(by default/factory setting, the IP address of the netHOST is
0.0.0.0
).
·
The netHOST device must be properly configured with the SYCON.net
configuration software. The configuration needs to be downloaded to
the device. As an alternative, the netHOST can also be configured by
the accessing host system.
For detailed information on how download firmware to the
NHST-
T100-EN
device and how to configure all netHOST devices with
SYCON.net, see Operating Instruction Manual
Configuration of LAN
controlled master devices
–
netHOST
, DOC130402OIxxEN, stored
on the netHOST Solutions DVD in the Documentation\english
\1.Software\SYCON.net directory.