Hardware description
17/152
4.2
Interfaces
4.2.1
Power supply
See position
(11)
in section
DC 24V
Pin
Signal
Description
+
+24 V DC
+24 V DC
-
GND
Ground (Reference potential)
FE
Functional earth
Table 4: Power supply connector
4.2.2
LAN connectors
The two RJ45 connectors (see positions
(5)
and
(7)
page 14]) allow you to connect your device to your IT
network, respectively to the cloud (e.g. the netFIELD Portal).
The MAC addresses of the LAN interfaces are printed on the device label.
Note that the “factory setting” for the IP address of the LAN port 1 (eth0) is
DHCP mode (“fallback” is
link-local
, i.e. address block
169.254.0.0/16
).
The “factory setting” for the IP address of the LAN port 2 (eth1) is
192.168.253.1
You can change the IP address settings in the Local Device Manager (see
section
page 55]).
4.2.3
Real-Time Ethernet connectors
The two RJ45 connectors (see positions
(13)
and
(15)
page 14]) allow you to connect your device to a Real-
Time Ethernet network (OT network).
The MAC addresses of the RTE interfaces are printed on the device label
(“Fieldbus MAC addr.”)
Note that you must deploy software containers featuring the corresponding
applications (e.g.
netFIELD App PROFINET Device
) on the device in order
to use the Real-Time Ethernet interface.
Note:
The RTE interface can also be used like a standard Ethernet TCP/
IP interface with limited data throughput. (In this case, “multicasts”
are not supported.)
If you want to do so, you can enable this option in the
Local Device
Manager
under
General Settings
>
OT Interface
(see section
Interface (Using the cifx0 interface or RTE)
information).
netFIELD OnPremise | User manual
DOC200901UM02EN | Revision 2 | English | 2021-06 | Released | Public
© Hilscher 2021