COMX 10CN-COS
Immunity COMX 10CN-COS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2 kV
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
A
Table 48: Product Tests COMX 10CN-COS – Immunity
4.1.5
COMX 10CA-DPS
Immunity COMX 10CA-CCS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 8 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2.2 kV
B
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
B
Table 49: Product Tests COMX 10CA-DPS – Immunity
4.1.6
COMX 10CN-DPS
Immunity COMX 10CN-CCS
Generic Standard
Basic Standard Test
Test level
Error
Class
Electrostatic Discharge
Air discharge
+ 10 kV
B
EN 61000-4-2
Contact discharge
+ 6 kV
B
Burst
EN 61000-4-4
Communication lines (shielded)
+ 2.5 kV
A
Surge
EN 61000-6-2 (2006-03)
Industrial Environment
EN 61131-2 (2008-04)+A11, A12
Programmable Controllers
EN 61000-4-5
Communication lines (shielded)
1 kV
A