Technical Data
246/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
DHCP is not supported
IRT “flex” (synchronized RT Class 2) is not supported
FastStartUp is not supported.
Media Redundancy (except MRP client) is not supported
Access to the submodule granular status bytes (IOCS) is not supported.
The amount of configured IO-data influences the minimum cycle time
that can be reached.
Supervisor-AR is not supported, Supervisor-DA-AR is supported
Only 1 Input-CR and 1 Output-CR are supported
Multiple WriteRequests are not supported
Using little endian (LSB-MSB) byte order for cyclic process data instead
of default big endian (MSB-LSB) byte order may have an negative impact
on minimum reachable cycle time
Reference to firmware/stack version
V3.4.x.x
Table 180: Technical Data PROFINET IO RT IRT Device Protocol
10.4.13 PROFINET IO-Device (V3.13)
Parameter
Description
Maximum number of cyclic input data
1440 bytes
Maximum number of cyclic output data
1440 bytes
Maximum number of submodules
255 submodules per Application Relation at the same time,
1000 submodules can be configured
Multiple Application Relations (AR)
The Stack can handle up to 8 IO-ARs, one Supervisor AR and one
Supervisor-DA AR at the same time
Acyclic communication
Read/Write Record, max. 8 KB (fragmented)
Alarm Types
Process Alarm, Diagnostic Alarm, Return of SubModule Alarm,
Plug Alarm (implicit), Pull Alarm (implicit), Update Alarm, Status Alarm,
Isochronous Problem Alarm, Upload and Retrieval Notification Alarm
Supported protocols
RTC – Real Time Cyclic Protocol,
class 1 (unsynchronized), class 3 (synchronized)
RTA – Real Time Acyclic Protocol
DCP – Discovery and configuration Protocol
CL-RPC – Connectionless Remote Procedure Call
LLDP – Link Layer Discovery Protocol
SNMP – Simple Network Management Protocol
MRP – MRP Client
Topology recognition
LLDP, SNMP V1, MIB2, physical device
Identification & Maintenance
Read and write of I&M0-5, Read of I&M5
Minimum cycle time
1 ms for RT_CLASS_1
250 µs for RT_CLASS_3
IRT Support
RT_CLASS_3
Media Redundancy
MRP client is supported
Asset Management
Max. 199 assets
PROFIenergy PROFIenergy
ASE
implementation with one PE entity per submodule
Additional features
DCP, VLAN- and priority tagging, Shared Device (max. 1 RTC3 AR)
Baud rate
100 MBit/s
Data transport layer
Ethernet II, IEEE 802.3
PROFINET IO specification
V2.2 (legacy startup) and V2.3
Limitations
RT over UDP not supported.