Please make sure all chemical solution is evacuated from the hose before commencing high pressure rinsing. Fail-
ure to do so could result in atomizing cleaning or disinfecting solution.
To select desired chemical, point selector to corresponding product using the arrow on the selector switch.
When using hydrogen peroxide-based products like Suprox and Suprox-D, always make sure to purge the selector valve
daily. Prolonged exposure to hydrogen peroxide can damage the selector valve.
To evacuate product from selector valve, remove the corresponding product cap and dispense solution for about 15-sec-
onds. Repeat with each selector position.
Maintenance:
Daily:
1)
Run one to two gallons of fresh water through the unit after use. This will purge the lines and gun of any residual
chemical.
2)
Flip the power switch to the off position. Relieve the pressure in the discharge hose by pulling the trigger on the
application gun, once the machine is switched off.
3)
Check the unit for any visible damage or leaking.
4)
Purge hydrogen peroxide-based products from system by following the instructions in “normal operation”
section.
5)
If the unit is stored where there is a possibility of freezing temperatures, drain the water reservoir and run the
pump until all water is purged from the system. Allow the unit to thaw before engaging the pump again.
Periodic:
1)
Soak both spray tips in Hillyard Extra Strength CSP to minimize blockage and protect the pump from excessive
cycling.
2)
Remove in-line bowl filter from underside of machine and clean. If there is water in the reservoir, it will drain
out with the filter removed.