background image

4

7EN160183 Rev. 8  •  2020

www.hillrom.com

 

Before lifting, keep the following points in mind:

•   A responsible person within your organization should decide on a case-by-case basis whether one or more caregivers are 

needed.

•  Ensure that the sling selected meets the patient’s needs with reference to model, size, fabric and design.
• For safety and hygiene reasons, use individual slings.
•  Plan the lifting operation so that it can be done as safely and smoothly as possible.
• Check that the lifting accessory hangs vertically and can move freely.

•   

Although Liko’s slingbars are equipped with latches, special caution must be exercised. Before the patient is lifted from the 

underlying surface, but after the straps have been fully extended, make sure the straps are correctly connected to the sling 

bar hooks.

•  

Make sure the patient is sitting securely in the sling before transfering to another location.

•   

Never lift a patient higher off the underlying surface than is needed to complete the lifting and transfer procedure.

•   

Never leave a patient unattended during a lifting situation.

•   

Make sure that the wheels on the wheelchair, bed, gurney, etc., are locked during the lifting/transfer operation.

• Always work ergonomically. Use the patient’s ability to actively participate in the operations.
• When the sling is not being used, do not place in direct sun light.

 

Incorrect attachment of sling to slingbar may cause severe injury to the patient.

 

Manually turning the patient in bed may cause injuries to the caregiver. 

Safety Instructions

PATENT www.hillrom.com/patents

May be covered by one or more patents. See above Internet address.

The Hill-Rom companies are the proprietors of European, US, and other patents and pending patent applications. 

Product Changes

Liko®

 products undergo continuous development, which is why we reserve the right to make product changes without prior 

notice. Contact your Hill-Rom representative for advice and information about product upgrades.

Design and Quality by Liko in Sweden

Liko is quality certified according to ISO 9001 and its 

equivalent

 for the medical device industry ISO 13485.Liko is also certified 

according to environmental standard ISO 14001.

Notice to Users and/or Patients in EU

Any serious incident that has occurred in relation to the device, should be reported to the manufacturer and the competent 

authority of the Member State in which the user and/or patient is established.

  

Medical Device Class 

I

 Product

Summary of Contents for 35300304

Page 1: ...who are especially sensitive due to muscle or joint pain ComfortSling Plus is often suitable even for amputees because it provides support under the entire sitting surface ComfortSling Plus High Mod...

Page 2: ...ling Plus to a Sling Bar with 4 Hooks Twin Bars and Cross Bars 7 Lifting from a Supine Position 7 Returning to the Supine Position 8 Removing the Sling 8 Lifting from the Floor 8 Lifting to a Wheelcha...

Page 3: ...l Number Medical device Do not dry clean Do not iron Tumble drying Do not tumble dry Washing Symbol is always in combination with recommended temperature in C and F Latex Free Periodic inspection Do n...

Page 4: ...ney etc are locked during the lifting transfer operation Always work ergonomically Use the patient s ability to actively participate in the operations When the sling is not being used do not place in...

Page 5: ...r Hill Rom representative Recycling Instructions The entire sling including laths padding material etc should be sorted as Combustible waste Hill Rom evaluates and provides guidance to its users on th...

Page 6: ...7EN160183 Rev 8 2020 www hillrom com Sling bar Sling loops to sling bar hooks Correct SlingGuard Universal SlingGuard Twin Universal Twin Cross bar Wrong How to Attach a Sling to Different Sling Bars...

Page 7: ...the sling as far in under the patient as possible and with its lower edge just below the bend in the patient s knees Fold the sling a couple of times so that its center back strap follows the patient...

Page 8: ...lower edge of the sling should be just below the bend in the patient s knees Raise the back support First connect the upper strap loops to the sling bar then the lower strap loops See page 6 7 for ins...

Page 9: ...ll The sling should cover at least half of the bottom of the thigh to ensure a safe lift If this is not the case the patient should be positioned manually to an appropriate position NOTE Excessive for...

Page 10: ...ling Plus Mod 350 in combination with Liko Universal SlingBar 450 provides a comfortable reclined sitting position 2 Liko ComfortSling Plus Mod 350 in combination with a twin bar 670 provides a reclin...

Page 11: ...220 lbs 67 cm 26 5 in 153 cm 60 5 in The indicated patient weight is only a guideline there may be deviations If the patient has poor muscle tone and sinks too low in the ComfortSling you should cons...

Page 12: ...bars please contact Hill Rom Other combinations Combinations of accessories products other than those recommended by Liko can result in risks for the safety of the patient Recommended combinations of...

Reviews:

Related manuals for 35300304