Functional Description

The RPD-2200 is a dual dynamics processor with link option for expansion, gating, compressing, peak 
limiting, de-essing and enhancing of audio signals. Automation functions for compression param-
eters, comprehensive manual parameter adjustment options and level virtualizations make this unit 
suitable for a large variety of applications in recording, live sound and installation environments. 

2

1

3

4

9

10

7

8

6

11

5

AC inlet and fuse holder. Use the supplied AC cord to connect the unit to AC mains. Make sure 
voltage and frequency stated and set on the unit comply with your local AC supply. The fuse 
can be accessed by the small drawer at the AC inlet. To change the fuse, unplug the AC cord 
first, pull out the fuse drawer and replace the fuse ONLY with a fuse of SAME voltage and 
rating. If the fuse blows again after replacement, hand over the unit to qualified service person-
nel. 

CHANNEL XLR INPUT. This is a balanced XLR connector wired in parallel with the TRS connec-
tor (3).

CHANNEL TRS INPUT. This is a balanced TRS connector wired in parallel with the XLR connec-
tor (2).

SIDECHAIN SEND. This is the unbalanced sidechain output, which allows you to route the audio 
signal to other devices for external processing.

SIDECHAIN RETURN. The sidechain input allows you to use an external signal or the processed 
(e.g. with an equalizer) audio signal routed from the SIDECHAIN SEND jack for external control.

OPERATING LEVEL switch. This switch can be used to adapt to various operating levels, i.e. to 
toggle between home recording level (-10 dBV) and studio level (+4 dBu). The level meters will 
be referenced automatically to the nominal level adjusted, so that the compressor works in its 
optimum operating range.

CHANNEL XLR OUTPUT. This is a balanced XLR connector wired in parallel with the TRS 
connector (8).

CHANNEL TRS OUTPUT. This is a balanced TRS connector wired in parallel with the XLR 
connector (7).

EXPANDER/GATE TRIGGER. This control determines the threshold below which expansion 
sets in, so that signals below threshold are reduced in gain. The setting range is from OFF to 
+10 dB.

EXPANDER/GATE DISPLAY. If a signal below the adjusted value is applied, the left red LED 
(expansion on) lights up. If the signal gain is above the adjusted value, the right white LED lights 
up.

EXPANDER/GATE DISPLAY RELEASE switch with LED. To adapt the expander/gate optimally 
to the program material, use this switch to select a short or long release time. Percussive 
material with little or no reverb at all is usually processed with a short release time (switch not 
pressed). The long release time is the best choice for slowly decaying or heavily reverberated 
signals (switch pressed).

EXPANDER/GATE MODE switch with LED. This switch toggles between the expander function 
(switch not pressed) and the gate function (switch pressed). Use the gate function to mute 
signals below threshold (e.g. noise).

COMPRESSOR THRESHOLD. This control adjusts the compressor threshold from -40 to +20 
dB.

13

12

USER MANUAL - RPD2200 COMPRESSOR LIMITER

Summary of Contents for RPD-2200

Page 1: ...RevA 06 2017...

Page 2: ...nections to and from the product are neither subject to potentially des tructive mechanical impact nor present any risk of stumbling or other accident risk to people Audio equipment may generate sound...

Page 3: ...ized recycling stations Unpacking Please check that the box contains the following items Main parts 1 pc RDP 2200 main unit 1 pc Mains cable 1 pc Operation manual If any part is missing please contact...

Page 4: ...PAGE 3 Controls and Connections 8 1 7 2 3 5 4 USER MANUAL RPD2200 COMPRESSOR LIMITER 10 9 30 13 15 19 22 17 20 23 25 6 14 18 26 11 16 21 24 27 12 28 29 37 33 34 36 32 35 31...

Page 5: ...r external control OPERATING LEVEL switch This switch can be used to adapt to various operating levels i e to toggle between home recording level 10 dBV and studio level 4 dBu The level meters will be...

Page 6: ...in path and thus avoids the pumping effect caused by high energy bass frequencies and their influence on the compression process COMPRESSOR ATTACK control This determines when the compression sets in...

Page 7: ...tch with LED This switch adapts the de esser to the male switch pressed or female registers not pressed DE ESSER LEVEL DISPLAY This LED chain shows the attenuation within a range from 3 to 12 dB DE ES...

Page 8: ...r mixer to a low level Set the audio output of any audio processor between the mixer and the amplifier s to a medium level if any such processors Turn up the volume controls of your amplifier s slowly...

Page 9: ...ctions red shield black tip sleeve tip sleeve red tip shield sleeve red tip black sleeve shield uncon 3 1 2 plug side 3 1 2 cable side red 2 black 3 shield 1 red 2 shield 1 3 2 3 1 3 1 2 3 1 2 cable s...

Page 10: ...try s of purchase requirements on the function of the electronic circuitry we hence have to limit the warranty on such electro mechanical parts to 90 days from the date of purchase In many cases malfu...

Page 11: ...PAGE 10 USER MANUAL RPD2200 COMPRESSOR LIMITER...

Page 12: ...N60065 2014 ROHS2 Directive 2011 65 EU and is marked as follows Authorized Signature Place and date of issuing www hill audio com Hill Audio products are developed manufactured and distributed by Adel...

Reviews: