HIKVISION TURBO HD 5 MP User Manual Download Page 14

 

LIVE DPC, WHITE DPC and BLACK DPC are adjustable in 

this section. 
LIVE DPC: Detects and corrects the dynamic or the 

real-time defective pixels occur during the using. ON, and 
OFF are selectable. The correction level from 0 to 255 is 

configurable if the LIVE DPC is set as ON, set it as OFF to 

disable the live defective pixel correction. 
WHITE DPC: White DPC is the pixel on CCD or CMOS 
sensor that appear completely white. Move the cursor to 

the white DPC, and press Iris+ to enter the white DPC 

configuration interface. 
BLACK DPC: Black DPC is the pixel on CCD or CMOS 

sensor that appear completely black. Move the cursor to 
the white DPC, and press Iris+ to enter the black DPC 
configuration interface. 
LANGUAGE 
Supports English, and Chinese. 

3.8

 

ADJUST 

In the ADJUST sub-menu, you can configure the settings, 
including the sharpness, monitor, and the LSC (lens 

shading compensation). Move the cursor to ADJUST 

and click Iris + to enter the adjust configuration 
interface. 

ADJUST

 SHARPNESS                             
 MONITOR                  
 LSC                               
 RETURN           

AUTO



OFF

RET

 

Figure 3-6

 

ADJUST 

SHARPNESS 
Sharpness determines the amount of detail an imaging 

system can reproduce. And you can adjust the 
sharpness from 0 to 15. The higher the value, the 

clearer and sharper the image appears. 
MONITOR 
GAMMA
BLUE GAIN, and RED GAIN are selectable. 
GAMMA is the name of a nonlinear operation used to 
code and decode luminance or tristimulus values in 

video or still image system

with USER, 0.45, 0.50, 0.55, 

0.60, 0.65, 0.70, 0.75, 0.80, 0.85, 0.90, 0.95, and 1.00 
are selectable. 
BLUE GAIN can be adjusted from 0 to 100. 
RED GAIN Can be adjusted from 0 to 100. 
LSC 
Lens shading correction corrects the phenomenon that 
the image gets darkened or blurred on the periphery. 
Set it as ON, move the cursor to SCAN and click Iris+ to 

correct the lens shading. Set it as OFF to disable the 

LSC. 

3.9

 

EXIT   

RESET 
Move the cursor to RESET and click Iris+ to reset all the 
settings to the default. 
NOT SAVE 
Move the cursor to NOT SAVE and click Iris+ to exit the 
menu without saving the settings   
SAVE & END 
Move the cursor to SAVE & END and click Iris+ to save 
the setting and exit the menu. 

Summary of Contents for TURBO HD 5 MP

Page 1: ...or requests do not hesitate to contact the dealer This manual may contain technical incorrect places or printing errors and the content is subject to change without notice The updates will be added t...

Page 2: ...his device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marke...

Page 3: ...heating or a fire hazard Make sure that the plug is firmly connected to the power socket When the product is mounted on wall or ceiling the device shall be firmly fixed If smoke odor or noise rise fr...

Page 4: ...t Features The camera is applicable for both indoor and outdoor conditions and the application scenarios include road warehouse underground parking lot bar etc The main features are as follows High pe...

Page 5: ...f the wall is cement you need to insert expansion bolts before you install the camera If the wall is wooden you can use self tapping screws to secure the camera If the product does not function proper...

Page 6: ...djusting screw 3 Loosen the No 2 adjusting screw to adjust the tilting position 0 to 90 4 Tighten the No 2 adjusting screw 5 Loosen the No 3 adjusting screw to adjust the rotation position 0 to 360 6...

Page 7: ...body Figure 2 6 Fix the Junction Box Cover back to its Body 9 Refer to step 6 of 2 1 1 Ceiling Wall Mounting without Junction Box to complete the installation 2 2 Installation of Type II Camera 2 2 1...

Page 8: ...pening 6 Install the main body to the mounting base and insert the clip plate Figure 2 10 Install the Turret Camera 7 Tighten the screws with the wrench 8 Connect the corresponding cables such as powe...

Page 9: ...6 mm 30 mm 62 6 mm 62 6 mm Figure 2 12 Drill Template of the Junction Box 3 Refer to step 3 of 2 2 1 Ceiling Wall Mounting without Junction Box to take out the camera s main body 4 Take apart the jun...

Page 10: ...ct the camera with the TVI DVR and the monitor shown as the Figure 3 1 2 Power on the analog camera TVI DVR and the monitor to view the image on the monitor 3 Click PTZ Control to enter the PTZ Contro...

Page 11: ...to the number of the pixels can be displayed on the image You can set the resolution as 5 megapixels or 4 megapixels The higher the value the finer the image is FRAME RATE Frame rate refers to the num...

Page 12: ...n set the AGC value from 0 to 15 The AGC is disabled if the value is set to 0 BRIGHTNESS Brightness refers to the brightness of the image You can set the brightness value from 1 to 10 to darken or bri...

Page 13: ...AY NIGHT Color B W and Auto are selectable for DAY NIGHT switch COLOR the image is colored in day mode all the time B W the image is black and white all the time and the IR LED turns on in the low lig...

Page 14: ...ation interface ADJUST SHARPNESS MONITOR LSC RETURN AUTO OFF RET Figure 3 6 ADJUST SHARPNESS Sharpness determines the amount of detail an imaging system can reproduce And you can adjust the sharpness...