Example SMS command send
Description
Example SMS command
response
1234 Disarm 0
1234 = User Code. Disarm 0 = Will disarm
in Area 0
Disarm; Area 0
1234 Disarm ABCD0123
1234 = User Code. Disarm ABCD0123 =
Will disarm in Areas ABCD0123.
Disarm; Area ABCD0123
NOTE: If no areas are specified then all areas will disarm (default).
Arming with inputs bypassed via SMS text command
1234 Arm 0 Bypass 4
1234 = User Code. Arm 0 Bypass 4 = Arms
Area 0 and will bypass Input 4
Input Bypass; Area 0 Input 04
Force Arm: Area 0
1234 Arm 0 Bypass Kitchen
1234 = User Code. Arm 0 Bypass Kitchen =
Arms Area 0 and will bypass the Input
named Kitchen.
Input Bypass; Area 0 Kitchen
Force Arm: Area 0
Bypassing inputs via SMS text command
1234 Bypass 6
1234 = User Code. Bypass 6 = In the next
arming procedure, Input 6 will be
bypassed.
Input Bypass; Area 0 Input 06
1234 Bypass Garage
1234 = User Code. Bypass Garage = In the
next arming procedure, and will bypass the
Input named Garage.
Input Bypass; Area 0 Garage
NOTE: Output names have to be one word and spelled exactly as written in the panel e.g. Garage Door is not acceptable. It has
to be written as Garage-Door in the panel and the respective command will be Garage-Door.
Checking the system status via SMS text command
1234 Status
1234 = User Code. Status.
Area 0 Disarmed No Faults
Area 1 Disarmed No Faults
Area 2 Disarmed No Faults
Area 3 Disarmed No Faults (etc.)
Operating the user automation outputs via SMS text commands
1234 Output 1 On
1234 = User Code. User Output 1 turns on.
OUTPUT 1 ON
1234 Output Garage-Door On
1234 = User Code output
Garage-Door on = Turns output named as
Garage-Door on.
OUTPUT Garage-Door ON
1234 Output Garage-Door Off
1234 = User Code output
Garage-Door off = Turns output named as
Garage-Door off.
OUTPUT Garage-Door OFF
NOTE: Output names have to be one word and spelled exactly as written in the panel e.g. Garage Door is not acceptable. It has
to be written as Garage-Door in the panel and the respective command will be Garage-Door.
NOTE: The user automation outputs can also be activated via the keypad or the keyfob.
Checking the user automation outputs status via SMS text commands
1234 Output 1
1234 = User Code. User Output 1 status
check.
OUTPUT 1 ON or OUTPUT 1 OFF
1234 Output Garage-Door Status
1234 = User Code. Output Garage-Door
status check.
OUTPUT Garage-Door ON or
OUTPUT Garage-Door OFF
NOTE: Output names have to be one word and spelled exactly as written in the panel e.g. Garage Door is not acceptable. It has
to be written as Garage-Door in the panel and the respective command will be Garage-Door.
PCX User Guide
102017853 - V01
35