DS-PRI120 Security Radar User Manual
UM DS-PRI120 091720NA
63
concentrated, there may be a false alarm when there is glass in the radar scene.
The higher the sensitivity, the more probability to trigger a false alarm.
D.9
Why Is the Camera Unable to Track the Target?
•
The camera is not calibrated.
•
The camera is not linked to the zone.
D.10
Common Mistakes of Calibrating Camera
Prompt when selecting target: Please select the calibration target trajectory
Reason: Target not selected or disappears when acquiring parameters.
Solution: Select the moving target for parameter acquisition.
Prompt when adding calibration points: Error in parameter range, illegal range: T <=0
Reason: The angle of pitch, T, of the speed dome is less than or equal to 0.
Solution: Adjust the angle of pitch of the speed dome so that T is greater than 0.
Prompt when adding calibration points: Incorrect Parameters
Reason: The status of the linked camera device is offline.
Solution: Reconnect the camera. Make the status of the camera is online to continue calibration.