1 Disassembling the Detector
2
The Printed Circuit Board(PCB)
3
4
5 Installation Hints
6 The 12 m Lens
7 Resistor Wiring
8 Choose the Connection Type
9 Powering up
10
11
Dimension and Weight
(a) Lens (b) LED Light Pipe
(c) Lens Holder
(e) Nut
(d) PCB
(f) Casing Screw
DS-PDD12-EG2
12 m Pet Immune Dual-Tech Detector
(g) Alarm
Resistor Headers
1K, 2K2,
4K7, 5K6, 6K8
(a) PIR Sensor
(f) Terminals
(h) Tamper
Spring
(e) Tamper
Resisitor Headers
1K,2K2,
4K7,5K6
1
1
2
2
3
3
(1) Ceiling Bracket Fitting (Non EN compliant)
(2) Wall Bracket Fitting
(2) Single End of Line Wiring
(1) Normally Closed
(3) Double End of Line Wiring
99 g
(3.5 oz)
1
2
3
4
The detector has two method for resistor wiring:
(1) Using headers to select the End of Line resistance
(Control panel dependent)
on the ALARM/TAMPER header pins.
(2)
Select an resistance (Control panel dependent), and add the resistor to
ALARM/TAMPER wiring ports of the detector.
Note:
If EOL (End of Line) wiring is not used, leave the headers OFF. If the headers and the header pins does not match, do not
force the header, please select the method 2 to wire the resistor. Method 1 and method 2 should not be used on the
ALARM/TAMPER at the same time.
Technical Specification
85.9°
(a) Detection Range
(b) Mounting Height
52 zones
4 planes
Mounting height range from
1.8 m to 2.4 m.
The recommended
mounting height is 2.2 m.
=
=
(a) Alarm
Resistance
(b) Tamper
Resistance
1K,
2K2,
4K7,
5K6,
6K8
1K,
2K2,
4K7,
5K6
©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
It includes instructions on how to use the Product. The software
embodied in the Product is governed by the user license agreement
covering that Product.
About this Manual
This Manual is subject to domestic and international copyright
protection. Hangzhou Hikvision Digital Technology Co., Ltd.
(“Hikvision”) reserves all rights to this manual. This manual cannot be
reproduced, changed, translated, or distributed, partially or wholly,
by any means, without the prior written permission of Hikvision.
Trademarks
and other Hikvision marks are the property of Hikvision
and are registered trademarks or the subject of applications for the
same by Hikvision and/or its affiliates. Other trademarks mentioned
in this manual are the properties of their respective owners. No right
of license is given to use such trademarks without express
permission.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the EMC Directive
2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the
purchase of equivalent new equipment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info
UD17437B
IC Information
CLASS B: CAN ICES-3 (B)/NMB-3(B)
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of
a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary
for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique
à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à
l'établissement d'une communication satisfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur
et votre corps.
FCC Information
Please take attention that changes or modification not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that
may cause undesired operation
a. Alarm Control Panel
a. Alarm Control Panel
b. Detector
b. Detector
a. Alarm Control Panel
b. Detector
After powering on, the indicator flashes rapidly. Once the
detector self test is completed, the LED indicator will go
out until the detector detects movement.
45.5 mm
65.7 mm
103.8 mm
Class B: This device is intended for mainly home use (Class B) and
may be used in all areas
B
급 기기
:
이 기기는 가정용
(B
급
)
전자파적합기기로써
주로
가정에서 사용하는 것을 목적으로 하며
,
모든 지역에서 사용할
수 있습니다
.
The connection shows
the example:
1. Normal: 1K
2. Alarm: 2K
3. Tamper: 0 K or infinite
The connection shows
the example:
1. Normal: 1K
2. Alarm: Infinite
3. Tamper: 0 K
NOT READY
READY
(j) Sensitivity Settings
LOW
AUTO (Default)
HIGH
(i) LED ON/OFF
LED ON
LED OFF
Screw Model
number
PA_3.5 ×25
4
Installation Method - Detector Backplane Installation
Installation Method - Bracket Installation
1K
10m
12m
1m 2m
4m
6m
8m
10m
12m
1m
2.4m
2m
4m
6m
8m
10m
12m
1m
2m
4m
6m
8m
ALARM
TAMPER
6K8
5K6
4K7
2K2
1K
+
-
ALARM
TAMPER
EOL
EOL
5K6
4K7
2K2
1K
ALARM
TAMPER
6K8
5K6
4K7
2K2
1K
+
-
ALARM
TAMPER
EOL
EOL
5K6
4K7
2K2
1K
ALARM
TAMPER
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
+
-
ALARM
TAMPER
EOL
EOL
ALARM
TAMPER
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
+
-
ALARM
TAMPER
EOL
EOL
ZONE2
CO
M
ZONE1
CO
M
+
-
ALARM
TAMPER
+
-
6K8
5K6
4K7
2K2
1K
ALARM
TAMPER
EOL
EOL
5K6
4K7
2K2
1K
ALARM
TAMPER
+
-
6K8
5K6
4K7
2K2
1K
ALARM
TAMPER
EOL
EOL
5K6
4K7
2K2
1K
ALARM
TAMPER
+
-
6K8
5K6
4K7
2K2
1K
5K6
4K7
2K2
1K
ALARM
TAMPER
EOL
EOL
ZONE2
CO
M
ZONE1
CO
M
+
-
ZONE2
CO
M
ZONE1
CO
M
+
-
1K
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS
PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR
PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL
HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO
YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION,
IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF
PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT
TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE
OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK,
VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT
LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO
ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION
SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE
APPLICABLE LAW, THE LATER PREVAILS.
(d) Microwave Module
(b) AND/OR Mode
(c) Microwave Range Control
Max: 12 m
Medium: 0 to 12 m
Min: 0 m
EN50131-1:2006+A1:2009+A2:2017
EN 50131-2-4:2008
Security Grade 2
Environment class II
(c)
50Hz as default
60Hz remove header
Note:
Brackets are optional.
Brackets sale separately.
Note: PET immunity is
available up to 12 m and at a
height that is below the top
plane of view.
To use the pet immunity function,
please install a pet mask.
Sensi
ti
vity mode High Auto Low
Weight
5 kg 10 kg 15 kg
PET Table
Detec
ti
on range
12m, 85.9°
Detec
ti
on speed
0.3 to 2 m/s
Sensi
ti
vity
High, Auto, Low
Auto sensi
ti
vity
Yes
Onboard EOL
Yes
Digital temperature compensa
ti
on Yes
Technology
Digital microprocessor based
SEC technology
Yes
Sealed op
ti
cs
Yes
Creep zone protec
ti
on
Yes
Direct light
fi
lter
6500lux
Tamper protec
ti
on
Front
LED indicators
Green(PIR), Orange(microwave), Blue(alarm)
Microwave frequency
24Ghz (24.1
92
5Ghz to 24.
21
25Ghz)
Microwave range
Poten
ti
ometer adjustment
AND/OR mode
PIR / MW
Pet immunity
10Kg (With op
ti
onal pet mask)
Power supply
9 to 16 VDC (standard: 12 VDC)
Current consump
ti
on
< 15 mA (12 VDC) - Both quiescent and alarm
Opera
ti
ng temperature
-10 °C ot 55 °C (14 °F to 131 °F)
Storage temperature
-20 °C ot 60 °C (-4 °F to 140 °F)
Opera
ti
ng humidity
10% to 90%
Installa
ti
on height
1.8 to 2.4m
Dimension (H × W × D)
103.8 mm × 65.7 mm × 45.5 mm
Weight
99 g
Bracket
Op
ti
onal wall & ceiling accessory
Low is non EN and non INCERT compliant.