![HIKVISION DS-KAD308 User Manual Download Page 20](http://html.mh-extra.com/html/hikvision/ds-kad308/ds-kad308_user-manual_2131859020.webp)
13
Table 4-10
RW1 Configuration for More than One Distributor
Digit
(RW1)
1
2
3
4
5
6
7
8
Floor No.
Status
OFF
OFF OFF
*
*
*
*
ON
1 floor with 12
households
ON
OFF
OFF
*
*
*
*
ON
2 floors with 6
households each
OFF
ON
OFF
*
*
*
*
ON
3 floors with 4
households each
ON
ON
OFF
*
*
*
*
ON
4 floors with 3
households each
OFF
OFF
ON
*
*
*
*
ON
6 floors with 2
households each
* means irrelevant, ON means 1, OFF means 0.
Digit 1 and Digit 2 (RW1) are set as OFF by default, means 1 floor with 12 households.
Digit 8 (RW1) is used to set the distributor mode. ON means the current indoor
station version, OFF means the former version.
2.
Set the digit value of Digit 4, Digit 4 and Digit 6 to define the room No..
Table 4-11
RW1 Configuration for More than One Distributor
Digit
(RW1)
1 2 3
4
5
6
7 8
Room No. of
F1
F2
F3
F4.
F5
Status
* * *
OFF
OFF
OFF
* *
1
-12
1-6
1-4
1-3
1-2
* * *
ON
OFF
OFF
* *
13-
24
7-
12
5-8
4-6
3-4
* * *
OFF
ON
OFF
* *
25-
36
13-
18
9-1
2
7-9
5-6
* * *
ON
ON
OFF
* *
37-
48
19-
24
13-
16
10-
12
7-8