3) Click Upgrade to start upgrading.
Note
Do not power off during the upgrading.
7.10.5 Configure RS-485 Parameters
You can set the RS-485 parameters including the baud rate, data
bit, stop bit, parity type, communication mode, work mode, and
connection mode.
Steps
1. Click Maintenance and Management → Device to enter the
device list.
2. Press CTRL and click to enter the remote configuration page.
3. Click System → RS-485 Settings to enter the Configuring the
RS-485 Parameters tab.
4. Select the serial No. of the port from the dropdown list to set
the RS-485 parameters.
5. Set the baud rate, data bit, the stop bit, parity, flow control,
communication mode, working mode, and the connection
mode from the dropdown list.
6. Click Save and the configured parameters will be applied to the
device automatically.
Note
After changing the working mode, the device will be rebooted.
A prompt will be popped up after changing the working mode.
7.10.6 Manage User
Steps
1. Click Maintenance and Management → Device to enter the
device list.
2. Press CTRL and click to enter the remote configuration page.
3. Click System → User .
4. Click Add to add the user (Do not support by the elevator
controller.).
5. Optional: Select a user in the user list and click Edit to edit the
user.
You are able to edit the user password, the IP address, the
MAC address and the user permission.
6. Click OK.
7.10.7 Set Security
Steps
1. Click Maintenance and Management → Device to enter the
device list.
2. Press CTRL and click to enter the remote configuration page.
3. Click System → Security .
4. Select the encryption mode in the dropdown list.
5. You can select Compatible Mode or Encryption Mode.
Compatible Mode
118