Thermal Network Speed Dome Quick Start Guide
3
V
ID
EO
RED
AC
24V
YEL
LOW
/GR
EEN
BLA
CK
A
C24
V
YE
LLO
W
R
485
-
OR
AN
GE
R
485
+
Power Cable
RS485-
RS485+
Video Cable
Alarm Inputs
Network Cable
Alarm Outputs
Audio Input / Output
Figure 2-2
Cables of Thermal Speed domes
2.3
Alarm In/Out Connections
This section is only for the speed dome with alarm in/out functions.
The speed dome can be connected with alarm inputs (0~5VDC) and alarm outputs. Refer
to the following diagrams for alarm output:
JQC-3FG
Relay
30VDC
GND OUT
L
N
~
220V AC
Thermal speed
Dome
Relay Output
(10A 250VAC )
Diagram (left)
Diagram (right)
1A
OUT(n)
OUT(n)
+
-
DC
DC Load
Thermal Speed
Dome
Relay Output
OUT(n)
OUT(n)
Figure 2-3
Alarm Out Connections
The alarm provides the relay output (no voltage), and the external power supply is
required when it connects to the alarm device.
For DC power supply (left diagram), the input voltage must be no more than 30VDC,
1A.
For AC power supply, the external relay must be used (right diagram) to prevent
damages to the speed dome and avoid risk of electric shock.