Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
48
10.1.6 Full Screen
This function is used to view the image in full screen mode.
Click
to start full screen mode and press ESC button to exit.
10.1.7 Conduct Regional Focus
You can enable the function to focus on certain area.
Steps
1. Click
to enable regional focus.
2. Drag the mouse on the live view to draw a rectangle as the desired focus area.
3. Click
to disable this function.
10.1.8 Light
Click
to turn on or turn off the illuminator.
10.1.9 Operate Wiper
For the device that has a wiper, you can control the wiper via web browser.
Steps
1. Go to wiper setting page: Configuration → PTZ → Wiper.
2. Select a wiper mode.
One Time
The wiper wipes one time when you click
on live view page.
Cycle
The wiper works on schedule at set wiping interval. Click
on live
view to start wiping.
Duration
The schedule in which the wiper is ready to work.
Interval
The interval between two secessive wiping actions.
Auto
Note
Auto mode is only available for device that supports rain-sensing auto
wiper.