HIKVISION DS-2TD2117-6/V1 Configuration Manual Download Page 10

Performance Series Thermal Camera Configuration Guide 

CG PS Thermal Cameras 072619NA 

10 

 

Figure 10, VCA Resource Configuration

 

3.

 

Go to 

Configuration > Local

4.

 

Check the 

Live View Parameters: Display Temperature Info, Yes

 radio buttons. 

 

Figure 11, Live View Parameters 

5.

 

Go to 

Configuration > Temperature Measurement > Basic Settings

6.

 

Set the following items:

 

 

Channel No.:

 Use the pull-down menu to select the camera you want to configure. 

 

Enable Temperature Measurement:

 Check the checkbox.   

 

Display Min. Temperature: 

Check the checkbox. 

 

Display Average Temperature:

 Check the checkbox. 

Summary of Contents for DS-2TD2117-6/V1

Page 1: ...Performance Series Thermal 2CD TDxx17 x V1 Thermal Camera Configuration Guide...

Page 2: ...PONSIBILITIES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER HIKVISION WILL PROVIDE TIMELY...

Page 3: ...S Thermal Cameras 072619NA 3 Table of Contents Table of Contents Table of Contents Table of Contents Introduction 4 VCA Video Content Analysis 4 Temperature Measurement 9 Fire Source Detection 14 Disp...

Page 4: ...ies cameras 2CD TD1217 x V1 2CD TD2117 x V1 2CD TD2617 x V1 VCA Video Content Analysis 1 Enter the camera s IP address in a Web browser to access the camera s interface 2 Go to Configuration Maintenan...

Page 5: ...ation Basic Settings 8 Check the Intelligent Analysis checkbox 9 Click the Save button Figure 3 Display on Picture 10 Go to Configuration VCA Rule 11 Create one or more rules NOTE NOTE NOTE NOTE A Lin...

Page 6: ...the pull down menu to select how to filter the target To detect the target more accurately it is suggested to use Filter by Pixel Max Size Read Only The maximum target pixel size to detect Min Size Re...

Page 7: ...Maximum Size Icon Click to drag and place a box to define the maximum size target to detect Minimum Size Icon Click to drag and place a box to define the minimum size target to detect Line Icon Click...

Page 8: ...Performance Series Thermal Camera Configuration Guide CG PS Thermal Cameras 072619NA 8 Figure 7 Rule Settings Figure 8 Rule Settings Example 16 Verify the VCA effect rules in Live View...

Page 9: ...iguration Guide CG PS Thermal Cameras 072619NA 9 Figure 9 Live View Temperature Measurement 1 Go to Configuration Maintenance VCA Resource Type 2 Check the VCA Resource Configuration Temperature Measu...

Page 10: ...ers Display Temperature Info Yes radio buttons Figure 11 Live View Parameters 5 Go to Configuration Temperature Measurement Basic Settings 6 Set the following items Channel No Use the pull down menu t...

Page 11: ...rature Measurement Configuration Mode Use the pull down menu to select a mode Normal This mode will display the highest temperature and lowest temperature Expert This mode will let you create points l...

Page 12: ...the number of degrees that the Alarm Temperature needs to vary above or below depending on the Alarm Rule to cancel the alarm e g in the above example when the temperature falls below 37 C the alarm b...

Page 13: ...Performance Series Thermal Camera Configuration Guide CG PS Thermal Cameras 072619NA 13 Figure 15 Configuration Normal Figure 16 Configuration Expert...

Page 14: ...hermal Cameras 072619NA 14 Figure 17 Point Area Line Fire Source Detection 1 Make sure VCA Resource Type has been selected with the Fire Detection option Figure 18 VCA Resource Configuration 2 Make su...

Page 15: ...Thermal Cameras 072619NA 15 3 In the Fire Source Detection Basic section check the Enable Dynamic Fire Source Detection checkbox Figure 20 Enable Dynamic Fire Source Detection 4 Verify the Fire Source...

Page 16: ...VCA info temperature info and fire source info displayed together with the stream VCA info will be displayed on a third party platform Figure 22 Display VCA Info By Image 1 Set Palette Palettes let y...

Page 17: ...n Guide CG PS Thermal Cameras 072619NA 17 Figure 23 Palettes 2 Set PIP Settings The system can display the thermal view overlapped on the optical view and display the thermal view with overlaid detail...

Page 18: ...ical and thermal images luminance components 0 displays a fully optical image 100 displays a fully thermal image All color in the image is from the thermal image 4 Set the Border Fusion Ratio 0 100 Th...

Reviews: