Figure 8-6 Draw Area
9. Click Save.
10. Repeat above steps to set other regions.
11. Set arming schedule. See Set Arming Schedule .
12. Set linkage method. See Linkage Method Settings .
8.2.5 Set Region Exiting Detection
Region exiting detection is used to detect the objects movement of exiting from a predefined area.
When it occurs, the device takes linkage actions as response.
Steps
1. Go to VCA → Smart Event → Region Exiting Detection .
2. Select a channel.
3. Check Enable.
4. Optional: Click Lock to lock PTZ control to prevent the interruption from other PTZ related action
during configuration.
Normally, the PTZ control is automatically locked when you enter the configuration interface.
You can manually resume the lock when the countdown is over.
5. Adjust the live image to the desired scene by using PTZ control buttons.
Note
PTZ control is only available for Camera 01.
6. Draw detection area.
1) Select a Region No.. Up to 4 regions can be set.
Network PTZ Camera User Manual