5-i nch High Speed Dome User Ma nual
© Hikvision Digital Technology Co., Ltd. All Rights Reserved.
31
3.6.2
Configuring Line Synchronization
Purpose:
This speed dome supports user-defined line (external) synchronization of the signal.
Steps:
1.
Enter PTZ configuration menu:
MAIN MENU > DOME SETTINGS > LINE SINC
2.
Set the synchronization mode.
ON:
Enable the line synchronization. Adjust the phase of the line synchronization to synchronize
input power, with the line synchronization phase (V-phase) configurable from 0 to 255 degrees.
OFF
: Set the line synchronization off.
Note:
External synchronization is not supported.
LINE SYNC
LINE LOCK ON
V-PHASE 0
BACK EXIT
Figure 3-28
Synchronization Configuration
3.6.3
Restoring Default Dome Settings
Purpose:
You can reset all dome settings to factory default parameters as shown in the table below.
Note:
Dome settings are mainly of PTZ parameters and alarm parameters, and also include some
system settings, e.g. dome address.
Enter default dome settings menu:
MAIN MENU > RESTORE DEFAUTLS
Click
IRIS+
to restore the dome settings to the default value as shown in below table; or click
IRIS-
to
exit.
Table 3-3
Default Dome Settings
Parameters
Default Value
Dome address
0
Baud rate
2400bps
120Ω matching
resistance
Off
Soft address
Off