4.

 

Then you can see this page. The Add. Bit0 is the Broadcast address which means if 
you choose this channel, you can control all PTZ in the same time. But if you want 
to control the different PTZ, you need to set different Add. Bit for all of them. (You 
should notice that this Add need to match the address on the device.) 
E.g. If the SW1 switch on the PTZ 1 is 1, we need to set our Add. Bit as 1 too. And 
normally  the  default  Baud  Rate  is  2400.  For  the  Protocol,  you  can  choose  the 
HIKVISION. Then press OK button to save the setting. Then we have finished 1 
PTZ’s setting. You also need to configure another 4   

 

 

 

Notice: I have confirm with R&D colleague that all kinds of analog speed dome 
have  the  DIP  Switch.  So  you  just  need  to  find  it. And  make  sure  PTZ  have  the 
different address and do the setting as I mentioned above. 

 