42
Before Debounce
After Debounce
Trigger_in1
Trigger_in2
Trigger_in3
Trigger_in2
Trigger_in3
Debouncer Time
Debouncer Time
Debouncer Time
t
1
t2
t1
t
4
t1
t
6
(t1>t2, trigger signal is ignored)
(t1<t4, trigger signal outputs after delaying t1) (t1<t6, trigger signal outputs after delaying t1)
Figure 9-13 Debouncer Sequence Diagram
Note
If the configured debouncer time is larger than the pulse width of trigger signal, the trigger signal
will be ignored. Otherwise, the trigger signal will be outputted after delay.
6. You need to set related parameters of shaft encoder control in
Encoder Control
after selecting
Encoder Module Out
as
Trigger In Source
7. You need to set related parameters of frequency converter control in
Frequency Converter
Control
after selecting
Frequency Converter
as
Trigger In Source
for details.
Line + Frame Trigger Mode
In this trigger mode, both line trigger and frame trigger are enabled. The device image acquisition is
controlled by frame trigger signal and line trigger signal. The number of lines in a frame is controlled
by the frame height register, and the line rate is controlled by the line trigger signal provided by
external devices, and is also limited by the acquisition line rate. The line trigger signal only works
after the device receives the frame trigger signal.
9.3.5 Set Shaft Encoder Control
The device supports shaft encoder control function that the device receives signal A and signal B
with phase difference. After internal computing, the outputted signal of the shaft encoder can be