Highland Tank Ultra Clear Service Manual Download Page 5

Page 

5

 of 

 

UCSM 144 29/09/2020

 

 

High Water Levels 

1.

 

 Check that high water alarm float is operational.  Use spare float to test 
 

Low Air Pressure in System 

1.

 

With no alarm activated can be caused by faulty valves in air blower 

2.

 

Replace chamber block kit or pistons in blower if necessary 

 

Low Air Alarm 

1.

 

 Usually diaphragm broken in air blower or worn piston in Nitto air blower.  Replace 
chamber block kit or piston 

 

High Water Alarm 

1.

 

 Irrigation blockage 

2.

 

Stuck float control 

3.

 

Failed pump 

 

Desludge of Septic Chamber 

1.

 

Sludge build up is checked at each service 

2.

 

When levels rise to between 80cm and 100cm a full desludge of the primary tank is 
required or as required by governing bodies 

3.

 

Sludge build up depends upon the number of people using the system and product 
usage.  Time varies between 3 and 10 years 

4.

 

Note on comment section on service form when a full desludge is required 

 

Sample Service Form 
 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Ultra Clear

Page 1: ...2 4109 Email sales highlandtanks com au Website www ultraclear com au CONTENTS Introduction Tools Equipment Extra Equipment Safety Installation Page 2 Normal Functioning Servicing Page 3 Maintenance Service Page 3 Page 4 Low Water Clarity System Smelling High Water Levels Page 4 Low Air Pressure in System Low Air Alarm High Water Alarm Desludge of Septic Chamber Influent Sampling Points Page 5 Sam...

Page 2: ...Free chlorine and PH test kits 7 Phillips head and flat head screw drivers 8 Carry bucket 9 Chlorine in small covered container 10 DO dissolved oxygen meter if required Extra Equipment 1 10 litre bucket with gauze scoop 2 Kerosene 3 Insect spray 4 Sludge pump 5 Sludge pump hoses and connections 6 Garden hose on reel 7 Quick flow submersible pump Safety 1 Hepatitis vaccinations reccommended 2 Avoid...

Page 3: ...en first entering the property 4 Close all gates etc when entering and leaving the property 5 A Service Report Form must be completed for each service in triplicate owner Council and file copy fill in customer details using run sheet on Service Form Maintenance Service 1 Remove manhole covers 2 Prior to putting on gloves use dip to remove water sample from pump chamber 3 Take chlorine residual rea...

Page 4: ...s ceased 4 If water is stained in colour a reddish or brown this could be caused by hair dyes and will not necessarily affect the performance of the system Chlorine residual level may need to be increased 5 Disinfectants and antiseptics may decrease water clarity This is indicated by dead bacteria scum build up in settling chamber The scum return will not remove this during normal operation as the...

Page 5: ...ston in Nitto air blower Replace chamber block kit or piston High Water Alarm 1 Irrigation blockage 2 Stuck float control 3 Failed pump Desludge of Septic Chamber 1 Sludge build up is checked at each service 2 When levels rise to between 80cm and 100cm a full desludge of the primary tank is required or as required by governing bodies 3 Sludge build up depends upon the number of people using the sy...

Page 6: ...odours Yes No If Yes what action is recommended Alarms tested and functional Yes No If not functional what action is recommended Final Effluent Quality Tested Yes No Disinfected Yes No Chlorine tablets remaining Yes No Quality Satisfactory Unsatisfactory On what evidence is this judgment made If Unsatisfactory what action was recommended Land Application Area Surface ponding Yes No Run off Yes No ...

Reviews: