TROUBLESHOOTING PROCEDURES
If any part of the system is not working use the following
troubleshooting procedure to isolate the failed component.
Then contact High Tech Pet Products Customer Support to
get it repaired or replaced.
1)
Test Base Station Transmitter
a)
First disconnect the boundary wire loop from the
base station transmitter by lifting the small door on
the bottom of the transmitter and pressing the two
wire connection buttons (one is black the other is
red) while pulling gently on the wires.
b)
Apply power to the transmitter and verify that the BREAK
DETECTION circuit indicates a break. There will be an
audible alarm and a message on the transmitter face. If a
break is NOT indicated, the base station transmitter has
failed – repair or replace.
c)
Make a Test Loop Wire as follows: Strip 1/2. inch
of insulation from the two ends of a 2.4-inch-long
piece of spare insulated wire. You can use any
gauge wire.
d)
Attach the Test Loop Wire to the loop terminals (black
and red) on the bottom of the transmitter. Apply power
to the transmitter and verity the BREAK DETECTION
circuit does NOT indicate a break. There should be no
audible alarm and no Break message on the transmitter.
If a break is detected the Base Station Transmitter has
failed – repair or replace.
2)
Test all Humane Contain Collar
e)
With the TEST Loop Wire attached and the transmitter
powered adjust the transmitter Boost Power switch to
normal (NOR) and the Field Strength Control knob to
maximum (fully clockwise). Now