Install Outer Arm
1. Place the appropriate lift arm assembly in the lift heads.
2. Install the lift head pins in to the lift head and through the holes in the arm assembly.
3. Each arm restraint gear can be oriented in a Left or Right configuration on the arms. Each arm
and arm restraint gear must be positioned in the proper location in the lift head
4.Install Arm Lock assembly in to the lift
5. Install Arm lock pins in to the lift
6. Pull up arm lock rod to ensure it is fully unlocked, adjust in this state. Adjust nut as shown.
7. Adjust the arm lock. Follow the arrow direction.