A-12 Studio Color User’s Manual
Lens Interior
To clean the interior of the lens, perform the following procedure:
1. Disconnect power from the unit. If the unit has been in operation, allow it to
cool for at least five minutes.
2. Unlatch the latches on the top and bottom of the bezel. Refer to Figure A.1.
Figure A.1. Removing the Bezel
3. Detach the safety cable from the bezel and pull the bezel off unit.
4. Wipe with a soft damp cloth or tissue, or use a small vacuum to remove the
built-up dust and dirt.
5. Replace the bezel and safety cable.
6. Relatch the bezel.