A-4
Studio Color User’s Manual
L A M P
O U T E R R
lamp has extin-
guished during
operation
•
dead lamp
•
power supply failure
•
replace lamp, refer
to "Replacing the
Lamp" on page A-
11
•
refer to qualified
service personnel
L A M P
T O U T
E R R
lamp time-out error
•
lamp too hot to
restrike
•
dead lamp
•
ignitor error
•
allow time for the
lamp to cool, and
home the fixture to
restrike the lamp
•
replace lamp, refer
to "Replacing the
Lamp" on page A-
11
•
refer to qualified
service personnel
L I N K
B U S Y
other data present
on the link during a
cross load
•
controller is still con-
nected to the link
•
disconnect control-
ler
L I N K
E R R
link error
•
bad cable(s)
•
no data
•
bad data
•
output from previous
fixture is bad
•
bad comm board
•
test and replace
cable(s) as neces-
sary
•
test data line
•
test data line
•
test by bypassing
previous fixture
•
refer to qualified
service personnel
O V E R
value counter is out
of range
•
lamp strikes, lamp
hours, or fixture hours
have rolled over 9999
•
reset the out of
range item
O V E R
T E M P
fixture is over tem-
perature
•
temperature is too
high
•
fixture is too close
to a major heat
source
•
check and reduce
ambient tempera-
ture
Table A.1:Display Error Messages