SolaHyBeam 2000 User Manual
41
v1.3
Focus wheel Er
(Focus wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Focus - movement is not located in the default position after the reset.
Zoom wheel Er
(Zoom wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Zoom - movement is not located in the default position after the reset.
Iris wheel Er
(Iris wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Iris - movement is not located in the default position after the reset.
Blade1wheel Er
(Blade1 wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Blade1 - movement is not located in the default position after the reset.
Blade1 Rot wheel Er
(Blade1 Rot wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or it’s driving IC on the main PCB). The Blade1 Rot - movement is not located in the default position after
the reset.
Blade2wheel Er
(Blade2 wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Blade2 - movement is not located in the default position after the reset.
Blade2 Rot wheel Er
(Blade2 Rot wheel- error) This message will appear after the reset of the fixture if the heads
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or it’s driving IC on the main PCB). The Blade2 Rot - movement is not located in the default position after
the reset.
Blade3 wheel Er
(Blade3 wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Blade3 - movement is not located in the default position after the reset.
Blade3 Rot wheel Er
(Blade3 Rot wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or it’s driving IC on the main PCB). The Blade3 Rot - movement is not located in the default position after
the reset.
Blade4 wheel Er
(Blade4 wheel- error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it’s driving IC on
the main PCB). The Blade4 - movement is not located in the default position after the reset.
Blade4 Rot wheel Er
(Blade4 Rot wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or it’s driving IC on the main PCB). The Blade4 Rot - movement is not located in the default position after
the reset.
Summary of Contents for SolaHyBeam 2000
Page 1: ...USER MANUAL Version 1 3 Revision A...
Page 2: ...SolaHyBeam 2000 User Manual 2 v1 3...
Page 4: ...SolaHyBeam 2000 User Manual 4 v1 3...
Page 7: ...SolaHyBeam 2000 User Manual 7 v1 3 DECLARATION OF CONFORMITY...
Page 8: ...SolaHyBeam 2000 User Manual 8 v1 3...
Page 16: ...SolaHyBeam 2000 User Manual 16 v1 3 Photometric data image...
Page 18: ...SolaHyBeam 2000 User Manual 18 v1 3 DIMENSIONAL DRAWINGS...
Page 37: ...SolaHyBeam 2000 User Manual 37 v1 3...