3. Installation for LED Light:
1. Bolt fountain base securely to flooring using 1/4” screws. NOTE: Fountain base can be
installed as a freestanding base not required to be bolted down.
2. Check Local Codes for Junction Box installation requirements. Ensure that the length of
exposed cord in the fountain is no more than 10 feet (3 m.), see Fig 1.
3. Cut the cord at the Junction Box, leaving at least 6 inches of cord to make connections.
4. Strip 6 inches of the outer cord jacket to expose the three insulated wires – be careful not to
damage the insulation on the three inner wires.
5. Position the Fountain Fixture as desired in the fountain.
6. If required by Local Ordinances, use the supplied bonding lug kit with the Fountain Fixture to
ensure proper bonding of light.
7. Fill the fountain until the light is completely submerged in water before operating it. Entire
fixture must be at least 2 inches below minimum operating water level.
8. Turn on main switch or circuit breaker, as well as the switch that operates the light itself, to
check for proper operation. Refer to Operating Instructions.
Fig. 1
WARNING!
Never operate this underwater light for more than 2 minutes
unless it is totally submerged in water. Without total
submersion, the light assembly will get extremely hot, which
may result in serious burns or in breakage of the lens. This
may result in serious injury to installers, bystanders, or in
damage to property.