YOU WILL NEED
TOTAL ELECTRICAL REQUIREMENTS
Voltage Rating
220 -240AC
Frequency Rating 50HZ
Power Rating
3.0KW
Other than steam generator
Internal Circuit Voltage is
12V
Internal Current Rating
0.17A
Your electrical contractor should understand
ALL
legal requirements of connection before undertaking any work or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!!
Note for electrician. This product comes with 13 amp plug(s) fitted with an RCD unit. We leave it this way for you to connect this your own way due to continued additions
to current regulations. As at October 2010 we offered two methods.
1) Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version
2) (Preferred) Wire into isolated fused feed connecting directly to the house consumer/service box. Remove the fitted plug and ensure the Consumer unit has capabilities to
replace RCD feature if RCD is removed.
Always use protection against electrical surge. Your shower should be treated the same as a home computer. A surge protector should eradicate the possibility of either
the transformer or computer control being burnt out. Please note earth is required and found on chassis of shower tray. A further earth is required from Steam Generator
unit. Each earth must ground through power supply line.
Requirements
Scissors
Stanley Blade
Silicone Gun
Spirit Level
Tape Measure Philips Screwdriver Electric Drill