f.  To change the membranes (3rd & 4th stage) follow the process as described in 

point 4.4 of this manual having previously removed the used membranes with the 

help of an adjustable wrench.

g.  To change the postfilter (5th stage), take off the right-hand-side cover of the ZENIT 

osmosis system (looking the system from the front) as indicated in point 4.4 of this 

manual.

h.  Once you have taken off the cover, remove the postfilter from their clamps, 

disconnect the tube from the inlet elbow at the entrance and the stem elbow at 

the exit of the cartridge postfilter. To do so, you must remove the corresponding 

security clips. Finally unscrew the elbows on the postfilter.

 

 

 

 

 

                                                                  

 

                                       

i.  Remove the postfilter from its original packaging. Remove the protection plugs 

at each end. Apply sufficient Teflon tape to the threads of the elbow pieces that 

we took off the used cartridge. Pay attention to the arrow on the cartridge which 

indicate the water flow. Make sure the cartridge is installed in the correct way 

because otherwise the water won’t flow correctly. Once you have made sure, screw 

on the corresponding elbows pieces to the cartridge (the inlet elbow is for ¼” tube 

and the output elbow is for ⅜” tube). Place the cartridge on the corre-sponding 

clamps, insert the tube in the inlet elbow and the ⅜” stem elbow in the output, 

insert it fully and replace the security clips we took off previously.

*The life of the filters and membranes will vary depending on the quality of the 

water supply, the usage and the amount of impurities it has.

**The duration of the membranes will be approximately 2 – 3 years given that mains 

wa-ter’s salinity is equal to or inferior to 1.000 ppm and the hardness is between 0 – 15ºF. If 

the water supply’s characteristics, if applicable, are different, then the conditions regard-

ing the replacement of the membranes will change.

Replace the cartridges in the given period to ensure the life of the membranes and 

the quality of the water obtained. 

a.  Close the ball valve of the feed adapter (Figure-9) and unplug the system from the 

electricity supply.

b.  Open the faucet (Figure-3) to relieve the pressure from inside the osmosis system.

c.  To change the carbon GAC (1st stage) and carbon CTO (2nd stage) cartridges, take 

off the right-hand-side cover of the ZENIT osmosis system (looking the system 

from the front) as indicated in point 4.4 of this manual.

d.  Once you have taken off the cover, remove the cartridges from their clamps, 

disconnect the tube from the elbows at the entrance and exit of the cartridge. To 

do so, you must remove the corresponding security clips. Then remove the car-

tridge from its clamps and unscrew the elbows on the cartridge. This process must 

be carried out for each of the cartridges you want to change.

  

 

e.  Remove the new cartridge from its original packaging; remove the protection 

plugs at each end. Apply sufficient Teflon tape to the threads of the elbow pieces 

that we took off the used cartridge. Pay attention to the arrow on the cartridge 

which indicate the water flow. Make sure the cartridge is installed in the correct way 

because otherwise the water won’t flow correctly. Once you have made sure, screw 

on the elbows pieces of the cartridge. Place the cartridge on the corresponding 

clamps, insert the ⅜” tube in the elbow pieces fully and replace the ⅜” security 

clips we took off previously. Each cartridge must be put in its corresponding 

position bearing in mind the order. This process must be carried out for each of the 

cartridges you want to change.

7.1.- Procedure for replacing cartridges and the membranes.

 

 

 

 

Summary of Contents for ZENIT

Page 1: ...USER INSTALLER S MANUAL MA ES RO ZENIT_RO 0236 02_FL_20_V02 RESIDENTIAL REVERSE OSMOSIS ...

Page 2: ...robiologically safe or has an unknown quality For water with a greater salinity level please contact your official distributor It is advisable that the water to be treated has been softened or with a maximum hardness of 15ºF for optimum performance Water with a hardness greater than 15ºF will shorten the life of the membranes If the water has a high concentration of iron or magnesium nitrate conce...

Page 3: ...lear Do not bend the tubes to prevent flow and pressure blockages Use original spare parts to assure the correct performance of the system For installation maintenance and cartridge change please follow this manual otherwise the warranty will be void 3 CHECKING THE CONTENTS Open the packaging and make sure that all of the components are inside ready for the installation X 1 X 2 X 1 X 1 FIGURE 1 FI...

Page 4: ...e osmosis system b The water supply input is designed to be used with hoses with a connection Insert the water feed adapter with the brass ball valve between the cold water supply and the hose Never install on the hot water connection as the osmosis system will be damaged Make sure that the brass ball valve is closed a The drain clamp is designed to adjust the sealing drainpipe to 1 b The drain cl...

Page 5: ...stem Figure 13 where it is marked IN inserting it fully Once it is inserted replace the security clip e The WATER STOP Antileak system Figure 13 must be fixed to the base of the unit where you re installing the osmosis system fixing it with the adhesives sup plied f Once you have fixed the WATER STOP Antileak system in the chosen place you must connect the tube to the outlet of the Antileak system...

Page 6: ...erly and tightened and the ZENIT system is connected to the 220 240V power supply g Close the brass ball valve at the water inlet Figure 9 and reconnect the tube to the inlet elbow CTO cartridge insert it fully and replace the safety clip Open again the water supply opening the brass ball valve Figure 9 h Open the faucet and let the water run between 6 10 minutes to remove the chemical product tha...

Page 7: ...mosis system The recommended maintenance of the osmo sis system is in the table below By not following the maintenance as described in this manual using original cartridges and by authorized per sonnel that guarantees the quality of the water produced and the correct operation of the osmosis system the warranty will be void 6 USER INTERFACE The ZENIT osmosis system has a user interface system made...

Page 8: ...ferior to 1 000 ppm and the hardness is between 0 15ºF If the water supply s characteristics if applicable are different then the conditions regard ing the replacement of the membranes will change Replace the cartridges in the given period to ensure the life of the membranes and the quality of the water obtained a Close the ball valve of the feed adapter Figure 9 and unplug the system from the ele...

Page 9: ... O rings on the membrane Damaged membrane hou sing Replace the membrane housing Membranes damaged Replace the membranes Badly connected tubes Wire the connection between the wastage and the permeate properly 3 Bitter or acidic taste Water with very low salinity level Fit a mineralizing post filter j Once you have changed one of the cartridges turn off the faucet Figure 3 plug the system into the e...

Page 10: ...ck the mains water pressure if it is greater than 3 bars check the correct working of pressu re regulator if it is not so replace it Leak in some point of the system and or faucet Repair the leak and or replace faucet 9 The osmosis system stops and starts Very little inlet pressu re less than 1 bar Bypass the low pressure switch Danger that the pump could work without water and break Low pressure ...

Page 11: ... y CTO cart change Membrane change Postfilter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Postfilter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO...

Page 12: ... 1 16 OI 0230 09 Feed adapter M x H x F 1 17 OI 0210 03 M x T Brass ball valve 1 18 OI 0207 45 2 simple clamp 2 19 TG A4TU4 Tee T x T x T quick connection 2 20 OI 0235 30 TDS Sensor 1 21 OI 0234 74 T 15A Maximum pressure switch 1 22 TG A6MC4 Male connector M x T 1 23 OI 0207 141 T 40 psi Pressure reductor 1 24 OI 0207 20 Drain clamp 1 25 OI 0207 139 WATER STOP Antileak system 1 26 TG A6TEU6 Stem E...

Page 13: ... 68 220 V 48 V Power supply 1 39 ME 2003 03 20x12 200GPD Membrane 2 40 TG A6BU6 T x T Bulkhead quick connection 2 41 TG A4BU4 T x T Bulkhead quick connection 1 42 TG A4ME4 Male Elbow M x T quick connection 2 43 OI 0205 18 2 x 10 Antibacterial Nanosilver in line post filter 1 44 OI 0207 116 Security clip 10 45 OI 0207 132 Security clip 24 46 OI 0207 133 Absorbent material for the Antileak system 2 ...

Page 14: ...26 27 MA ES RO ZENIT_RO 0236 02_FL_20_V02 MA ES RO ZENIT_RO 0236 02_FL_20_V02 NOTES NOTES ...

Page 15: ...0236 02_FL_20_V02 Hidro Water S L U Carretera Chirivella Aldaya 48 46960 Aldaya Valencia Spain Tel 34 961 98 62 30 hidrowater hidro water com www hidro water com DISTRIBUTOR INSTALLER Sale date Instalation date Stamp Stamp ...

Reviews: